integrated Distributed Acoustic Sensing (iDAS)

Version 9.12 by Sima Mousavi on 2024/01/29 16:27

What is iDAS?

iDAS stands for Integrated Distributed Acoustic Sensing. This advanced system utilizes the principle of Rayleigh backscattering in optical fibers to measure strain rates along the fiber's length. It's a cutting-edge technology predominantly used in fields like geophysics, where it's crucial for monitoring seismic activities, as well as in industrial applications like pipeline monitoring and security systems.

Safety first!

The iDAS uses a Class 1 laser, which is generally considered safe for most applications. However, direct exposure to the eye should be avoided to prevent any risk of eye injury.

Cables and fibers may create tripping hazards. Ensure that the routing of cables is done in a way that minimizes the risk of accidents.


System Components

The iDAS system consists of the following components:

  1. Interrogator unit: This unit houses the laser, detector, and electronics for processing the backscattered light signal. It records various settings such as the optical system configurations, spatial sampling rates, and the duration of data acquisition. More than one interrogator may be used in an experiment. Each unit should have a unique identifier and is described in its respective metadata block.
  2. Optical fiber: The optical fiber is the sensor that is used to measure strain rate.
  3. Data acquisition software: This software is used to control the interrogator unit and to acquire and process the data. It records various settings such as the optical system configurations, spatial sampling rates, and the duration of data acquisition.

DAS Data Collection System

1. Surface Installation

  • Cable Arrangement: The optical fiber cable can be a single long continuous cable or multiple cables with connectors, used across different installation environments.
  • Cable Types: Cables may vary in construction types based on the installation environment.
  • Geographical Metadata: Parameters related to geographical location are specified for easy searchability in databases.

2. Installation Environments

  • Shallow Burial: The cable can be shallowly buried.
  • In-Conduit Installation: The cable can also be installed within a conduit.
  • Water Installation: Suitable for underwater environments.

3. Channels

  • Sensor Distribution: Channels represent sensors distributed along the fiber array at fixed intervals.
  • Physical Location Determination: The physical locations of these channels are ascertainable through methods like tap tests and GPS tracking.
  • Metadata for Channels: Each channel or group of channels has its own metadata block, detailing specifics like location and properties.

1706489800616-982.png

1706488566274-805.png


DAS Metadata Schema

1. Interrogator

  • Required: Interrogator ID, manufacturer, model.
  • Optional: Serial number, firmware version.

2. Acquisition Parameters

  • Required: Interrogator ID, acquisition ID, unit of measure, acquisition start and end time, acquisition sample rate, gauge length, number of channels, spatial sampling interval.
  • Optional: Pulse rate, pulse width.

3. Overview

  • Required: Network code, location, start date, end date, point of contact.
  • Optional: Digital Object Identifier (DOI), purpose of data collection, funding agency.

4. Cable Information

  • Required: Cable ID, cable bounding box.
  • Optional: Cable owner, cable installation date, cable characteristics.

5. Fiber Information ('Native format')

  • Required: Cable ID, fiber ID, fiber geometry, fiber mode, fiber refraction index.
  • Optional: Fiber optical length, fiber start and end location, fiber one-way attenuation, fiber winding angle.

6. Channel Group

  • Required: Interrogator ID, acquisition ID, channel group ID, cable ID, fiber ID, coordinate generation date.
  • Optional: Location method, coordinate reference frame, first/last usable channel ID, uncertainty of various coordinates (x, y, latitude, longitude, elevation, depth, strike, dip).

7. Channel

  • Required: Channel group ID, channel ID, coordinates (x, y, latitude, longitude).
  • Optional: Elevation above sea level, depth below surface, distance along fiber, strike, dip.

Pre-processing Steps for DAS Data (2.5 months, 90 TB)

  1. Create a Deployment Log

    • Document key details like photonics settings, duration of data collection, instances of hard disk failure, power outages, etc.
  2. Generate Geographic Coordinates

    • Assign latitude and longitude coordinates to each DAS channel for spatial referencing.
  3. Data Conversion

    • Convert the raw DAS time series data from counts to strain rate, which is more meaningful for seismic analysis.
  4. Data Decimation

    • Reduce the sampling rate from 1000 Hz to 100 Hz. This step is essential to manage data volume and focus on frequencies of interest for seismic activities.
  5. Extract Specific Time Series

    • Isolate time series data of special interest, such as those related to earthquake events, for detailed analysis.
  6. Data Hosting

    • Store the processed data on Research School of Earth Sciences (RSES) clusters and the National Computational Infrastructure (NCI) for accessibility and further analysis.
  7. Extract Data and Instrument Response from Seismic Nodes

    • Retrieve both the raw data and the corresponding instrument response characteristics for accurate interpretation of the seismic signals.
  8. Long-term Archiving and Data Sharing

    • Ensure that the data is archived in a format and location that supports long-term preservation and accessibility, such as the AuScope Distributed Acoustic Sensing (DAS) Collection.
  9. Data Access and Record Keeping

    • Maintain records and access paths (e.g., NCI local file path) for the data, including metadata and other associated records, to facilitate future research and data sharing.

Operating System Compatibility:

  • The iDAS system software is designed to run on the Windows operating system, with the current version compatible with Windows 7.

Accessing the System:

  • User Login: The system is set up to log in automatically as "User", without requiring any credentials.
  • Software Shortcut: A shortcut to access the iDAS software is conveniently placed on the desktop for easy access.


Silixa iDAS Setup Manual for Reoccupying/Duplicating Experiment

General Information

  • Experiment Name: _______________________________________
  • Local Date: ____/___/202
  • Local Time: ___________________________________________
  • Personnel: ____________________________________________
  • Site Condition Notes:
    • [Space for detailed notes about the site condition, any upkeep performed, and changes made since the last visit.]

Setup Procedure

  1. Open iDAS Box

    • Serial Number: _________________
    • IP Address: ____________________
  2. Check Laser Lock

    • Ensure the lever on the LASER/RIGHT side of the iDAS is in the locked position (LEVER UP).
  3. Placement of iDAS

    • Position the iDAS on a stable surface.
    • Ensure clear air flow around the fan vents.
  4. UPS Setup (If applicable)

    • Connect the UPS to a power source.
    • Plug the NAS into the UPS using the special cable with a rectangular connector.
    • Connect the monitor to the UPS.
  5. Peripheral Connections

    • Connect a computer monitor, mouse, and keyboard to the iDAS.
  6. GPS Antenna Connection

    • Connect the GPS antenna to the left-side socket on the front of the iDAS using a special adapter.
  7. Fibre Optic Connection

    • Clean both the fibre optic cable and the socket with a 1-click cleaner before connection.
    • Use the guide/tip for cleaning the fibre and clean the socket without it.
  8. Powering the iDAS

    • Connect the iDAS to a power socket or UPS.
    • Note: The iDAS turns on automatically when connected to power. Use the power button at the bottom left if it does not.
  9. Network Drive Mapping

    • Open File Explorer and select 'This PC' from the left pane.
    • On the File Explorer ribbon, select 'More' > 'Map network drive'.
    • Choose a drive letter from the 'Drive' list.
  10. Open iDAS Software

    • Use the link/shortcut on the Desktop.
  11. GPS Satellite Confirmation

    • Check for a green light in the top row of the software interface indicating GPS satellite detection.
  12. Lever/Interlock Adjustment

    • Lower the lever/interlock (as mentioned in step 2) before starting data acquisition.
  13. Configuration File Duplication

    • Use 'current.cfg' for duplicating previous setup.
    • The file is located at C:/Silixa/Data/current.cfg.
    • Copy this file to the desktop and save it with a new filename.
  14. iDAS Configuration Settings

    • Navigate to the 'Configuration' tab and click 'iDAS configuration'.
    • Check all values under 'system'.
    • Under 'application', enable error messages.
    • In 'saving', select 'acoustic saving', choose 'tdms', and set the file save location and identifier.
    • Leave default parameters in 'measure'.
  15. Mode Selection

    • Toggle between Acoustic mode, Waterfall mode, and OTDR mode to check data recording.
  16. Photograph OTDR Mode

    • Document the OTDR mode settings with a photograph.
  17. Photograph Waterfall Mode

    • Similarly, take a picture of the Waterfall mode settings.
  18. Configuration File Saving

    • Save the configuration file in .cfg format in a separate location without overwriting the existing one.
  19. Software Check

    • Ensure QFinder, Teamviewer, and Microsoft Remote Desktop are installed.
  20. Remote Access Setup

    • Open Teamviewer or Microsoft Remote Desktop.
    • For Teamviewer, photograph the ID and password and ensure it remains open.
    • For Microsoft Remote Desktop, record the IP address and test remote access with a separate laptop.
  21. Final Mode Setting

    • Switch to OTDR mode for ongoing operation (avoids excessive memory usage of Waterfall mode).

Important Reminders

  • Always ensure that the iDAS is connected to a suitably earthed power socket or UPS for safety.
  • Regularly check the condition of all cables and connectors.
  • Before leaving the setup, confirm that data saving is active if required.
  • Keep a log of all actions taken during the setup for future reference and troubleshooting.
1706488806394-168.png

Caption

https://photos.fife.usercontent.google.com/pw/ABLVV86phmYsze0lp1yzL-gs6stE23rmgKbOxcpCRhFmK9s25zf5UHBkgbFcOg=w1440-h2556-s-no-gm?authuser=0

How to clean the optical connector

How to clean the optical connector