Changes for page Testing Procedures
Last modified by robert on 2024/12/09 16:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -612,25 +612,25 @@ 612 612 613 613 Inside the “Vrl (Theoretical)” cell enter the following formula using the corresponding cells. 614 614 615 - [Equation]615 +V_{RL}=I_{oc}\times R_L 616 616 617 617 618 618 Inside the “Rated Power” cell enter the following formula using the corresponding cells. 619 619 620 - [Equation]620 +P_{oc}=V_{oc}\times I_{oc} 621 621 622 622 623 623 Inside the “Load Power” cell enter the following formula using the corresponding cells. 624 624 625 - [Equation]625 +P_{RL}=\frac{V_{RL}}{R_L}\times V_{oc} 626 626 627 627 628 628 Inside the “Power Loss %” cell enter the following formula using the corresponding cells. 629 629 630 -The calculated values that are negative represent power loss, and positive values are power gain. Performing “conditional formatting” on these cells with colour gradient (defined by colour break limits) would yield visually easy to recognise defective panels. 630 +The calculated values that are negative represent power loss, and positive values are power gain. Performing “conditional formatting” on these cells with colour gradient (defined by colour break limits) would yield visually easy to recognise defective panels. 631 631 632 632 633 - [Equation]633 +Power\ Loss\ \%=\frac{P_{RL}}{P_{oc}}\times 100-100 634 634 635 635 636 636 Perform all the calculations for each solar panel ID entered.