... ... @@ -612,25 +612,25 @@
612 612  
613 613  Inside the “Vrl (Theoretical)” cell enter the following formula using the corresponding cells.
614 614  
615 -[Equation]
615 +V_{RL}=I_{oc}\times R_L
616 616  
617 617  
618 618  Inside the “Rated Power” cell enter the following formula using the corresponding cells.
619 619  
620 -[Equation]
620 +P_{oc}=V_{oc}\times I_{oc}
621 621  
622 622  
623 623  Inside the “Load Power” cell enter the following formula using the corresponding cells.
624 624  
625 -[Equation]
625 +P_{RL}=\frac{V_{RL}}{R_L}\times V_{oc}
626 626  
627 627  
628 628  Inside the “Power Loss %” cell enter the following formula using the corresponding cells.
629 629  
630 -The calculated values that are negative represent power loss, and positive values are power gain. Performing “conditional formatting” on these cells with colour gradient (defined by colour break limits) would yield visually easy to recognise defective panels. 
630 +The calculated values that are negative represent power loss, and positive values are power gain. Performing “conditional formatting” on these cells with colour gradient (defined by colour break limits) would yield visually easy to recognise defective panels.
631 631  
632 632  
633 -[Equation]
633 +Power\ Loss\ \%=\frac{P_{RL}}{P_{oc}}\times 100-100
634 634  
635 635  
636 636  Perform all the calculations for each solar panel ID entered.