... ... @@ -65,9 +65,9 @@
65 65  
66 66  Set-up an external power source, by connecting a solar regulator to a power supply  and set voltage to 18V DC. Verify the regulator is supplying the correct voltage of 7.7V and then plug into the “External Power” port of the recorder.
67 67  
68 -(% class="box infomessage" %)
68 +(% class="box warningmessage" %)
69 69  (((
70 -NOTE: There are two types of solar regulators available. Make sure to not mix them as they supply different Voltages, 7.7V and 13.8V.
70 +**IMPORTANT! **The LPR-200 now has two types of solar regulators. The new type (exclusive after Jan 1 2025) are modified to output 13.8V (for charging lead acid batteries directly). Do not use these with the old lithium battery packs as this may destroy the units and possibly explode! If you are confused email us.
71 71  )))
72 72  
73 73  Navigate to “System Information” in the Menu and note the battery icon will have a lightning symbol indicating it’s charging, also observe the state of charge % is increasing under.