Changes for page SmartSolo Node Seismometers
Last modified by robert on 2026/01/19 17:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,10 +23,11 @@ 23 23 24 24 The nodes must be programmed in the SoloLite software prior to use. The screenshots below show our recommended parameters for the 5 Hz (16HR-3C) and 5 second (BDC3-5) nodes. 25 25 26 -[[IGU -163C programming screen set at 250Hz. Ensurethat thecircled areas are set!>>image:5Hz_node_programming.labels.png||alt="IGU-16 3C programming screen"]]26 +[[IGU16HR-3C programming screen set at 250 hz. Ensure circled areas are set!>>image:5Hz_node_programming.labels.png||alt="IGU-16 3C programming screen" data-xwiki-image-label="IGU-16 3C programming screen set at 250 Hz. Ensure that the circled areas are set!"]] 27 27 28 -[[BD3C-5 programming screen set at 250 hz. Ensure that thecircled areas are set!>>image:5S_node_programming.labels.png||alt="BD3C-5 programming screen"]]28 +[[BD3C-5 programming screen set at 250 hz. Ensure circled areas are set!>>image:5S_node_programming.labels.png||alt="BD3C-5 programming screen set at 250 hz. Ensure that the circled areas are set!"]] 29 29 30 + 30 30 FIFO (first in, first out) data mode is safest as this will overwrite old data in case you forgot to clear the storage. At <= 250 hz you can fit 4++ months of data on these, shouldn't be an issue. 31 31 32 32 Note that the samplerate is instead given in sample spacing, in milliseconds. 4 ms = 250 Hz, 1 ms = 1000 Hz, 10 ms = 100 Hz, ad nauseam. ... ... @@ -126,10 +126,10 @@ 126 126 * **State of Charge (SoC) for Storage**: 127 127 ** Maintain a battery charge level of around 50-60% (i.e., ORANGE) for storage. 128 128 ** This charge level is recommended to prevent battery damage, and should be checked every six months. 129 -** Nodes should __not be stored at full-charge (GREEN), or 0-charge (RED).__ 130 +** Nodes should //__not be stored at full-charge (GREEN), or 0-charge (RED).__// 130 130 ** Storage at 0-charge damages lithium batteries**.** 131 131 * **SoC for Transport:** 132 -** Charge levels for transport will be advised by the freighter. The required SoC will usually fall between 0-60%dependingon method (air, land, sea).133 +** Charge levels for transport will be advised by the freighter. The required SoC will depend on volume and transport method (air, land, sea). 133 133 134 134 ((( 135 135 == 6. Data Sharing and Metadata Creation == ... ... @@ -415,21 +415,23 @@ 415 415 416 416 = **Cleaning** = 417 417 418 -When s till connected, the nodes are water resistant(don't submergethem!)andcan handle a good spray/wipe-down. A strong, non-wire brush is helpful to reach areas between the metal spikes on the bottom.419 +When assembled, the nodes are water resistant but not submersible. They can handle a good spray and wipe-down. A strong, non-wire brush is helpful to reach areas between the metal spikes on the bottom. 419 419 420 420 = **Weights (for shipping)** = 421 421 422 422 The weights of bags of nodes, as well as data harvesters and node chargers, are listed below: 423 423 424 -1 bag + 6 SP (IGU-16HR)nodes: 18 kg425 +1 bag + 6*IGU-16HR nodes: 18 kg 425 425 426 -1 SP (IGU-16HR)data harvester: 21.5 kg427 +1*IGU-16HR data harvester: 21.5 kg 427 427 428 -1 SP (IGU-16HR)charger: 26.3 kg429 +1*IGU-16HR charger: 26.3 kg 429 429 430 -1 BB (BD3C-5)charger/dataharvester(with and without 16 cables): 21 kg / 14.5 kg431 +1*BD3C-5 charger (with and without 16 cables): 21 kg / 14.5 kg 431 431 432 -1 case + 5 BB (BD3C-5) nodes and 6 BB nodes: 22 kg / 25 kg 433 +1 case + 5*BD3C-5 nodes: 22 kg (aggregate battery weight <5kg, 168Wh) 434 + 435 +1 case + 6*BD3C-5 nodes: 25 kg (aggregate battery weight >5kg, 168Wh) 433 433 ))) 434 434 435 435 (% class="col-xs-12 col-sm-4" %)
- 5S_node_programming.labels.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.KB - Size
-
... ... @@ -1,0 +1,1 @@ 1 +114.2 KB - Content