Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/10/29 10:39
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. JackD1 +XWiki.robert - Content
-
... ... @@ -44,18 +44,6 @@ 44 44 **Note that any applied instrument gain must be removed when exporting (e.g. to miniseed) after your deploy, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high! 45 45 {{/info}} 46 46 47 -=== **Programming tips**: === 48 - 49 -Connecting SmartSolo nodes to their harvesters and having SoloLite recognise them can be a bit tricky, here are some tricks to help register and program them easier: 50 - 51 - - Place the node on the harvester gently, then firmly press it down onto the pins 52 - 53 - - Place all nodes onto the harvester before trying any troubleshooting, as they may not show up while the SoloLite software is running. Once all are connected, try restarting the software for them to be recognised. 54 - 55 - - If a node is refusing to connect, try it with another slot. It is easiest if you place all 16 nodes on the harvester, and swap any nodes that refuse to connect with eachother 56 - 57 - - Nodes will likely not show up in the order that they should, though this is not an issue. Eg, a node in slot 6 on the harvester may show up in port 13 in the SoloLite software 58 - 59 59 = **Fieldwork Preparation** = 60 60 61 61 (% class="box warningmessage" %) ... ... @@ -250,6 +250,20 @@ 250 250 251 251 = **Downloading and Converting Seismic Data to MiniSeed Format** = 252 252 241 +(% class="wikigeneratedid" %) 242 +SmartSolo provides the following powerpoint for SmartSolo node programming and operation. Note that ANSIR only uses a portion of their process for our own uses: [[https:~~/~~/nappe.wustl.edu/smartsolo/files/smartsolo_online_training.pdf>>url:https://nappe.wustl.edu/smartsolo/files/smartsolo_online_training.pdf]] 243 + 244 +== Connection tips: == 245 + 246 +Connecting SmartSolo nodes to their harvesters and having SoloLite recognise them can be a bit tricky, here are some tricks to help register and program them easier: 247 + 248 +* Place the node on the harvester gently, then firmly press it down onto the pins. 249 +* Place all nodes onto the harvester before trying any troubleshooting, as they may not show up while the SoloLite software is running. Once all are connected, try restarting the software for them to be recognised. 250 +* If a node is refusing to connect, try it with another slot. It is easiest if you place all 16 nodes on the harvester, and swap any nodes that refuse to connect with each other. 251 +* Nodes will likely not show up in the order that they should, though this is not an issue. E.g, a node in slot 6 on the harvester may show up in port 13 in the SoloLite software. Annoying, but it doesn't matter so long as you keep track of what's been harvested! 252 + 253 + 254 + 253 253 == Node Registration and Software Setup == 254 254 255 255 1. (((