Last modified by robert on 2025/08/21 13:08

From version 74.2
edited by robert
on 2025/07/31 19:59
Change comment: There is no comment for this version
To version 77.1
edited by Jack Dent
on 2025/08/01 16:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.robert
1 +XWiki.JackD
Content
... ... @@ -4,12 +4,13 @@
4 4  (((
5 5  = **Node Types** =
6 6  
7 -ANSIR carry two types of three-channel nodes
7 +ANSIR carry two types of three-channel nodes, and one type of one-channel node:
8 8  
9 9  * **SmartSolo IGU 16HR 3C (5 Hz Short Period)**
10 10  * **SmartSolo BD3C-5 (5 Second Broadband)**
11 +* **SmartSolo IGU 16 1C (5 Hz Short Period, single channel)**
11 11  
12 -Both have a battery capacity of around 30 days. The programming, operation and downloading procedures for both types of SmartSolo nodes are also similar.
13 +All have a battery capacity of around 30 days. The programming, operation and downloading procedures for all types of SmartSolo nodes are also similar.
13 13  
14 14  ----
15 15  
... ... @@ -23,17 +23,25 @@
23 23  
24 24  FIFO (first in, first out) data mode is safest as this will overwrite old data in case you forgot to clear the storage. At <= 250 hz you can fit 4++ months of data on these, shouldn't be an issue.
25 25  
27 +Note that the samplerate is instead given in sample spacing, in milliseconds. 4 ms = 250 Hz, 1 ms = 1000 Hz, 10 ms = 100 Hz, ad nauseam.
28 +
26 26  Be sure to set the channel types to Seismic and the gain appropriately. For active source (i.e. explosions) you can leave the gain at 0, but for passive experiments some gain is purported to be helpful (although we have found this to be somewhat negligible). We can confirm that 6db for the broadband nodes and 24db for the short period works well.
27 27  
31 +If you want recording to begin immediately, ensure that begin date is in the past by at least a few days. If you prefer to have a timed turn-on, then set the times as needed. **Be warned that recording will not begin until a GPS lock is achieved, so if you set it to a future turn-on but bury it too deeply, it may not record!**
32 +
28 28  In newer versions of the software there is a "power consumption" setting.. we are no sure what this does exactly, but the manual says it gives life a "boost" at the expense of about 3 db of resolution. Until this can be quantified a bit better it is not recommended.
29 29  
30 -Storage type can be DLD (proprietary) or Miniseed. We assume the software works best with their proprietary format so prefer not to risk any issues. You can output to miniseed later.
35 +Storage type can be DLD (proprietary) or Miniseed. We assume the software works best with their proprietary format so prefer not to risk any issues. You can export to miniseed later.
31 31  
32 -GPS mode is best in cycle mode (e.g. once per hour) instead of constant. The clock drift on these are almost nil even if there is no sync at all, so it's best to conserve power.
37 +GPS is best set to cycle mode (e.g. once per hour) instead of constant "always on". The clock drift on these are almost nil even if there is no sync at all, so it's best to conserve power.
33 33  
39 +Bluetooth (BB nodes only) should be turned OFF to conserve power.
40 +
34 34  We recommend that the SP 16HR-3C be set to a gain of 24db for passive experiments and no higher than 250 Hz sampling rate unless there is an explicit reason to do so. The BD3C-5 should be set to a gain of 6db (which is the maximum allowed) for passive experiments (or 0 db if active).
35 35  
36 -**Note that this gain must be removed when exporting to miniseed, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high. We also recommend disabling bluetooth to increase battery life, and to enable "FIFO" mode just in case old data is still present on the units and you run out of space (although it is unlikely you will go over 64 Gb for one deploy). If using the "timed turn-on" option, please be aware that **the units will not begin recording until they have acquired a GPS lock**, which may nor occur if they are buried too deeply or have very poor sky view.
43 +{{info}}
44 +**Note that any applied instrument gain must be removed when exporting (e.g. to miniseed) after your deploy, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high!
45 +{{/info}}
37 37  
38 38  = **Fieldwork Preparation** =
39 39  
... ... @@ -328,7 +328,7 @@
328 328  
329 329  = **Cleaning** =
330 330  
331 -When still connected, the nodes are water resistant (don't submerge them!) and can handle a good spray / wipedown. A strong, non-wire brush is helpful to reach areas between the metal spikes on the bottom.
340 +When still connected, the nodes are water resistant (don't submerge them!) and can handle a good spray / wipe-down. A strong, non-wire brush is helpful to reach areas between the metal spikes on the bottom.
332 332  
333 333  = **Weights (for shipping)** =
334 334  
... ... @@ -427,7 +427,7 @@
427 427  (((
428 428  = SmartSolo IGU-16 Portable Battery Charger =
429 429  
430 -= [[image:20250729_124644.jpg]] =
439 +[[image:20250729_124644.jpg]]
431 431  
432 432  |**Dimensions (LxHxW)**|625 x 500 x 366mm
433 433  |**Input rating**|100-210V - 50/60Hz
... ... @@ -438,7 +438,7 @@
438 438  
439 439  (% class="box" %)
440 440  (((
441 -= SmartSolo BD3C-5 Carry Bag =
450 += SmartSolo BD3C-5 Carry Case =
442 442  
443 443  [[image:20250729_124957.jpg]]
444 444