1 +XWiki.robert
Content
... ... @@ -15,8 +15,24 @@
15 15  
16 16  = **Programming Defaults** =
17 17  
18 -We recommend that the SP 16HR-3C be set to a gain of 24db and no higher than 250 Hz sampling rate unless there is an explicit reason to do so. The BD3C-5 should be set to a gain of 6db (which is the maximum allowed). These are what we use for our internal experiments.
18 +The nodes must be programmed in the SoloLite software prior to use. Screenshots for the short period 16HR-3C and broadband BDC3-5 are shown with our recommended parameters.
19 19  
20 +[[IGU-16 3C (short period node) programming screen set at 250 Hz. Ensure that the highlighted areas are set!>>image:SP_programming.labels.png||alt="IGU-16 3C programming screen"]]
21 +
22 +[[BD3C-5 (broadband node) programming screen set at 250 hz. Ensure that the highlighted areas are set!>>image:BB_programming.labels.png||alt="BD3C-5 programming screen"]]
23 +
24 +FIFO (first in, first out) data mode is safest as this will overwrite old data in case you forgot to clear the storage. At <= 250 hz you can fit 4++ months of data on these, shouldn't be an issue.
25 +
26 +Be sure to set the channel types to Seismic and the gain appropriately. For active source (i.e. explosions) you can leave the gain at 0, but for passive experiments some gain is purported to be helpful (although we have found this to be somewhat negligible). We can confirm that 6db for the broadband nodes and 24db for the short period works well.
27 +
28 +In newer versions of the software there is a "power consumption" setting.. we are no sure what this does exactly, but the manual says it gives life a "boost" at the expense of about 3 db of resolution. Until this can be quantified a bit better it is not recommended.
29 +
30 +Storage type can be DLD (proprietary) or Miniseed. We assume the software works best with their proprietary format so prefer not to risk any issues. You can output to miniseed later.
31 +
32 +GPS mode is best in cycle mode (e.g. once per hour) instead of constant. The clock drift on these are almost nil even if there is no sync at all, so it's best to conserve power.
33 +
34 +We recommend that the SP 16HR-3C be set to a gain of 24db for passive experiments and no higher than 250 Hz sampling rate unless there is an explicit reason to do so. The BD3C-5 should be set to a gain of 6db (which is the maximum allowed) for passive experiments (or 0 db if active).
35 +
20 20  **Note that this gain must be removed when exporting to miniseed, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high. We also recommend disabling bluetooth to increase battery life, and to enable "FIFO" mode just in case old data is still present on the units and you run out of space (although it is unlikely you will go over 64 Gb for one deploy). If using the "timed turn-on" option, please be aware that **the units will not begin recording until they have acquired a GPS lock**, which may nor occur if they are buried too deeply or have very poor sky view.
21 21  
22 22  = **Fieldwork Preparation** =
... ... @@ -420,12 +420,18 @@
420 420  |**Slots no.**|16
421 421  )))
422 422  
439 +(% class="box" %)
440 +(((
441 += SmartSolo BD3C-5 Carry Bag =
423 423  
443 +[[image:20250729_124957.jpg]]
424 424  
425 425  
446 +|**Dimensions (LxHxW)**|590 x 225 x 405mm
447 +|**Weight**|8.2kg
448 +|**Slots no.**|6
449 +)))
426 426  
427 -
428 -
429 429  (% class="box" %)
430 430  (((
431 431  = SmartSolo IGU-16 3C Carry Bag =
... ... @@ -433,10 +433,10 @@
433 433  [[image:20250729_124502.jpg]]
434 434  
435 435  |**Dimensions (LxHxW)**|230 x 340 x 310mm
458 +|**Weight**|3.6kg
436 436  |**Slots no.**|6
437 437  )))
438 438  
439 -
440 440  (% class="box" %)
441 441  (((
442 442  = SmartSolo IGU-16 1C Carry Bag =
... ... @@ -444,6 +444,7 @@
444 444  [[image:20250729_124558.jpg]]
445 445  
446 446  |**Dimensions (LxHxW)**|225 x 200 x 550mm
469 +|**Weight**|
447 447  |**Slots no.**|6
448 448  )))
449 449  )))
20250729_124957.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.JackD
Size
... ... @@ -1,0 +1,1 @@
1 +532.5 KB
Content
BB_programming.labels.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.robert
Size
... ... @@ -1,0 +1,1 @@
1 +111.5 KB
Content
SP_programming.labels.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.robert
Size
... ... @@ -1,0 +1,1 @@
1 +106.7 KB
Content