Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/07/16 16:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,7 +11,6 @@ 11 11 12 12 Both have a battery capacity of around 30 days. The programming, operation, and downloading procedures for both types of SmartSolo nodes are also similar. 13 13 14 - 15 15 ---- 16 16 17 17 = **Programming Defaults** = ... ... @@ -20,7 +20,6 @@ 20 20 21 21 **Note that this gain must be removed when exporting to miniseed, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high. We also recommend disabling bluetooth to increase battery life, and to enable "FIFO" mode just in case old data is still present on the units and you run out of space (although it is unlikely you will go over 64 Gb for one deploy). If using the "timed turn-on" option, please be aware that **the units will not begin recording until they have acquired a GPS lock**, which may nor occur if they are buried too deeply or have very poor sky view. 22 22 23 - 24 24 = **Fieldwork Preparation** = 25 25 26 26 (% class="box infomessage" %) ... ... @@ -45,7 +45,7 @@ 45 45 46 46 = **Installation** = 47 47 48 -== **1. Logbook documentation** ==46 +== 1. Logbook documentation ~*~** TODO ADD LOGBOOK FORMS == 49 49 50 50 ((( 51 51 **Essential Details**: Record the following in a logbook: ... ... @@ -57,7 +57,7 @@ 57 57 * Serial number (SN) of the sensor 58 58 * Detailed notes on the site conditions and setup 59 59 60 -== **2. Node Placement**==58 +== 2. Node Placement == 61 61 ))) 62 62 63 63 **Protection**: Place nodes inside (landfill) biodegradable bags to minimize cleaning and cross-site soil contamination. ... ... @@ -68,12 +68,12 @@ 68 68 * Take multiple photographs from various angles to document the site setup thoroughly. 69 69 * Include a detailed site description in your notes, specifying distances and orientations from nearby landmarks (e.g. Richards garden, Te Mini steam field eastern side) 70 70 71 -== **3. GPS Considerations**==69 +== 3. GPS Considerations == 72 72 73 73 (% class="wikigeneratedid" %) 74 74 The GPS antenna is at the top and center of the unit, and will (usually) only receive signal with a clear sky view directly above. The signal is able to penetrate plastic and terracotta planters and a thin layer of soil, but may struggle if the soil layer is too thick. **These nodes will not start recording without attaining a GPS lock** and repeated attempts will excessively drain the battery. 75 75 76 -== **4. Visibility and Location Marking**==74 +== 4. Visibility and Location Marking == 77 77 78 78 **Flag Placement**: Position a flag, preferably in a bright color (avoid green or yellow), near the instrument to aid in its future location. 79 79 ... ... @@ -82,7 +82,7 @@ 82 82 * Use a GPS device to mark the instrument's exact location. 83 83 * Record this location in both your paper notes and the GPS device. 84 84 85 -== (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %) **5. Charge Time, Pre-Deployment & Post-Deployment**(%%) ==83 +== (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)5. Charge Time, Pre-Deployment & Post-Deployment(%%) == 86 86 87 87 * **Charging Duration**: Both types of nodes take approximately 6-8 hours to fully charge from a flat state. 88 88 * **Pre-Deployment Charging**: ... ... @@ -96,10 +96,10 @@ 96 96 * **Storage and Shipping Charge Level**: 97 97 ** Maintain a battery charge level of around 50-60% (e.g. "orange") for both storage and shipping purposes. 98 98 ** This charge level is recommended to prevent battery damage and is safe for transportation. 99 -** Nodes should not be stored fully charged, and it**they should especially not be stored with 0 charge.**97 +** Nodes should not be stored fully charged, and **they should especially not be stored with 0 charge as this damages lithium batteries.** 100 100 101 101 ((( 102 -== **6. Data Sharing and Metadata Creation**==100 +== 6. Data Sharing and Metadata Creation == 103 103 ))) 104 104 105 105 **GPS Data**: ... ... @@ -112,9 +112,9 @@ 112 112 113 113 **Metadata File**: 114 114 115 -* Create and organize metadata according to the [[ANU metadata standard txt file>>attach:example_metadata.txt]]. 113 +* Create and organize metadata according to the [[ANU metadata standard txt file>>attach:example_metadata.txt]]. This is going to be particularly important if you are reusing nodes at different sites... not documenting the serial numbers (of the **top half** of the node) and the times they were deployed can lead to station mix-ups. 116 116 117 -== **7. Additional Best Practices**==115 +== 7. Additional Best Practices == 118 118 119 119 * **Training and Familiarisation**: Make sure all team members are adequately trained in using the GPS devices, compass use, and other equipment to ensure consistent and accurate data collection. 120 120 ... ... @@ -169,25 +169,25 @@ 169 169 = **Charging Procedure for Seismic Nodes** = 170 170 171 171 ((( 172 -== **1. Preparation for Charging**: ==170 +== 1. Preparation for Charging: == 173 173 174 174 * Before charging, ensure each node is clean. This involves removing any dirt or debris to maintain the integrity of the equipment and ensure effective charging. 175 175 ))) 176 176 177 177 ((( 178 -== **2. Disassembling the Node**: ==176 +== 2. Disassembling the Node: == 179 179 180 180 * For the IGU-16HR, remove the battery (bottom half) from the sensor. This is done by unscrewing the spikes counter-clockwise. 181 181 ))) 182 182 183 183 ((( 184 -== **3. Setting Nodes in the Charging Box**: ==182 +== 3. Setting Nodes in the Charging Box: == 185 185 186 186 * Place 1-16 IGU-16HR battery components upside-down into the charger, assuring they are oriented properly. 187 187 ))) 188 188 189 189 ((( 190 -== **4. Monitoring the Charging Process**: ==188 +== 4. Monitoring the Charging Process: == 191 191 192 192 * Once the nodes are set in the charging box and the charging process begins, lights adjacent to the batteries will illuminate. These lights indicate that charging is underway. 193 193 * Observe the transition of the lights from steady red to orange, then to green, and finally to flashing green. A flashing green light signifies that the batteries are fully charged. For storage, the goal is to charge them to ORANGE. ... ... @@ -194,7 +194,7 @@ 194 194 ))) 195 195 196 196 ((( 197 -== **5. Updating Charge Status**: ==195 +== 5. Updating Charge Status: == 198 198 199 199 * During the charging period, take this opportunity to update the status of each unit. Check the //"C"// box on your temporary labels to indicate that the unit has been successfully charged. 200 200 * This step is crucial for tracking the charging status of multiple units, especially when handling a large number of nodes. ... ... @@ -211,7 +211,7 @@ 211 211 212 212 = **Downloading and Converting Seismic Data to MiniSeed Format** = 213 213 214 -== **Node Registration and Software Setup**==212 +== Node Registration and Software Setup == 215 215 216 216 1. ((( 217 217 **Registering Nodes in the System**: ... ... @@ -229,7 +229,7 @@ 229 229 * Ignore the settings for seismic recordings in the subsequent window. Resetting instruments (e.g., sampling rate, gain) requires reprogramming via script. 230 230 ))) 231 231 232 -== **Data Downloading Process**==230 +== Data Downloading Process == 233 233 234 234 1. ((( 235 235 **Initiating Data Download**: ... ... @@ -247,13 +247,13 @@ 247 247 * Click “prepare” followed by “run” to start reformatting. Monitor this process in the small panel at the bottom left. 248 248 * (% class="box warningmessage" %) 249 249 ((( 250 -* **Ensure to export data as "COUNTS", not "mV".** 248 +* **Ensure to export data as "COUNTS" (int32), not "mV" (float). This is critical!** 251 251 252 -* **Set "Remove Gain" to the same decibel gain as during programming ****(by default ANU sets this to 24db for short period nodes (a factor of 15.848932), and 6db for broadband nodes).**250 +* **Set "Remove Gain" to the same decibel gain as during programming. By default ANU sets this to 24db for short period nodes (a scaling factor of 15.848932), and 6db (a factor of 2.0) for broadband nodes.** 253 253 ))) 254 254 ))) 255 255 256 -== **Handling Nodes During Download**==254 +== Handling Nodes During Download == 257 257 258 258 1. ((( 259 259 **Monitoring Download Indicators**: ... ... @@ -270,6 +270,7 @@ 270 270 * **Use fast external hard drives to avoid limitations in data harvesting.** 271 271 272 272 * **Recommended specifications: USB-C, USB 3.0, and 4+ Tb of space.** 271 +* **The USB type for the harvester is TYPE-A, the typical normal rectangular shape.** 273 273 ))) 274 274 ))) 275 275 1. (((
- XWiki.XWikiComments[0]
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -Anonymous - Comment
-
... ... @@ -1,1 +1,0 @@ 1 -test comment - Date
-
... ... @@ -1,1 +1,0 @@ 1 -2025-07-16 15:59:01.66