Last modified by robert on 2025/06/16 07:51

From version 56.1
edited by robert
on 2025/06/15 17:48
Change comment: There is no comment for this version
To version 49.2
edited by Kimberley Berends
on 2024/05/29 15:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -SmartSolo Node Seismometers
1 +SmartSolo Nodes
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.robert
1 +XWiki.KB
Content
... ... @@ -104,8 +104,16 @@
104 104  
105 105  == **7. Additional Best Practices** ==
106 106  
107 +* **Environmental Responsibility**: Ensure that the node placement and the materials used are environmentally responsible and adhere to local regulations.
107 107  * **Training and Familiarisation**: Make sure all team members are adequately trained in using the GPS devices, compass use, and other equipment to ensure consistent and accurate data collection.
108 108  
110 +* (((
111 +==== **Keeping the Instruments Clean** ====
112 +)))
113 +* (((
114 +Use a (**landfill**, not //compost//) degradable bag when installing to keep the instrument clean. This will save you many hours of time cleaning them in preparation for their return. [[Here is a video>>url:http://auspass.edu.au/field/bd3c_removal.mp4]] demonstrating its effectiveness.
115 +)))
116 +
109 109  ----
110 110  
111 111  = **Seismic Station Demobilization and Documentation** =
... ... @@ -237,7 +237,7 @@
237 237  (((
238 238  * **Ensure to export data as "COUNTS", not "mV".**
239 239  
240 -* **Set "Remove Gain" to the same decibel gain as during programming** **(by default ANU sets this to 24db for short period nodes (a factor of 15.848932), and 6db for broadband nodes).**
248 +* **Set "Remove Gain" to the same decibel gain as during programming** **(by default ANU sets this to 24db (a factor of 15.848932).**
241 241  )))
242 242  )))
243 243  
... ... @@ -299,11 +299,8 @@
299 299  
300 300  **Procedure for Seismic Nodes:**
301 301  
302 -Top half:
310 +* If the nodes are placed in a sturdy plastic bag at the time of installation, the cleaning procedure should be straightforward. If not you have a lot of work to do before they are returned to us!
303 303  
304 -Bottom half: The metal spikes on the bottom half of the nodes can be cleaned using a wire brush, though should still be wiped down for dust afterwards.
305 -
306 -
307 307  = **Weights (for shipping)** =
308 308  
309 309  The weights of bags of nodes, as well as data harvesters and node chargers, are listed below:
... ... @@ -343,12 +343,8 @@
343 343  |(% style="width:189px" %)**Size (without spike)**|(% style="width:221px" %)158 x160mm
344 344  |(% style="width:189px" %)**Weight**|(% style="width:221px" %)2.8 kg
345 345  |(% style="width:189px" %)**Data Storage**|(% style="width:221px" %)64 Gb
346 -|(% style="width:189px" %)**Battery**|(% style="width:221px" %)(((
347 -Lithium-ion battery contained in equipment (168.84 Wh)
348 -
349 -UN3481 PI967 S1
351 +|(% style="width:189px" %)**Battery**|(% style="width:221px" %)Li_etc XXAh
350 350  )))
351 -)))
352 352  
353 353  (% class="box" %)
354 354  (((
... ... @@ -364,7 +364,7 @@
364 364  |(% style="width:187px" %)**Weight**|(% style="width:224px" %)2.4 kg
365 365  |(% style="width:187px" %)**Data Storage**|(% style="width:224px" %)64 Gb
366 366  |(% style="width:187px" %)**Battery**|(% style="width:224px" %)(((
367 -Lithium-ion battery contained in equipment (96.48 Wh)
368 +Lithium-ion (96.48 Wh)
368 368  
369 369  UN3481 PI967 S2
370 370  )))