Last modified by robert on 2025/06/16 07:51

From version 44.2
edited by robert
on 2024/05/14 18:39
Change comment: There is no comment for this version
To version 42.2
edited by robert
on 2024/03/25 12:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,24 +2,25 @@
2 2  (((
3 3  (% class="col-xs-12 col-sm-8" %)
4 4  (((
5 -= **Node Types** =
5 += **SmartSolo Node Types and Procedures** =
6 6  
7 -ANSIR carry two types of three-channel nodes
7 +**SmartSolo Node Variants:**
8 8  
9 -* **SmartSolo IGU 16HR 3C (5 Hz Short Period)**
10 -* **SmartSolo BD3C-5 (5 Second Broad-Band)**
9 +* **SmartSolo IGU 16HR 3C (5 Hz) Short Period Node**
10 +* **SmartSolo BD3C-5 (5-second) Broad-Band Node**
11 11  
12 -Both have a battery capacity of around 30 days. The programming, operation, and downloading procedures for both types of SmartSolo nodes are also similar.
12 +The installation, demobilization, and data downloading procedures for both types of SmartSolo nodes – the IGU 16HR 3C Short Period Node and the BD3C-5 Broad-Band Node are largely similar.
13 13  
14 +This uniformity in process ensures ease of operation across different node types, allowing for a streamlined approach in fieldwork and data management.
14 14  
15 15  ----
16 16  
17 -= **Programming Defaults** =
18 += **Node Setup** =
18 18  
19 -ANU recommends that the SP 16HR-3C be set to a gain of 24db and no higher than 250 Hz sampling rate. The BD3C-5 should be set to a gain of 6db (maximum allowed). These are what we use for our internal experiments. **Note that this gain must be removed when exporting to miniseed, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high. We also recommend disabling bluetooth to increase battery life, and to enable "FIFO" mode just in case old data is still present on the units and you run out of space (although it is unlikely you will go over 64 Gb for one deploy). If using the "timed turn-on" option, please be aware that **the units will not begin recording until they have acquired a GPS lock**, which may nor occur if they are buried too deeply or have very poor sky view.
20 +Short term (~~30 day) battery powered nodes. The default gain should typically be set to 24 db for the Short Period 16HR-3C and 6 db for the Broadband BD3C-5. **This gain must be removed when exporting to miniseed.**
20 20  
21 21  
22 -= **Fieldwork Preparation** =
23 +== **Pre-Fieldwork Preparation** ==
23 23  
24 24  (% class="box infomessage" %)
25 25  (((
... ... @@ -27,7 +27,7 @@
27 27  (((
28 28  **INVEST IN FAST EXTERNAL HARD DRIVES – DO NOT LET THIS BE THE LIMITATION OF DATA HARVESTING**
29 29  
30 -**Assume ~~1 Tb of storage for both raw and exported data per 50 nodes @ 250 Hz & 30 days. One node recording at 250 Hz for 30 days tends to create about 3 Gb of miniseed data.**
31 +**Assume ~~1 Tb of storage for both raw and exported data per 50 nodes @ 250 Hz & 30 days**
31 31  )))
32 32  )))
33 33  
... ... @@ -48,7 +48,7 @@
48 48  === **2- Node Placement** ===
49 49  )))
50 50  
51 -**Protection**: Place nodes inside (landfill) biodegradable bags to minimize cleaning and cross-site soil contamination.
52 +**Protection**: Place nodes inside thick, landfill biodegradable plastic bags for environmental protection and to minimize cleaning.
52 52  
53 53  **Site Analysis**:
54 54  
... ... @@ -59,7 +59,7 @@
59 59  === **3- GPS Considerations** ===
60 60  
61 61  (% class="wikigeneratedid" %)
62 -The GPS antenna is at the top and center of the unit, and will (usually) only receive signal with a clear sky view directly above. The signal is able to penetrate plastic and terracotta planters and a thin layer of soil, but may struggle if the soil layer is too thick. **These nodes will not start recording without attaining a GPS lock** and repeated attempts will excessively drain the battery.
63 +The GPS antenna is at the top and center of the unit, and will (usually) only receive signal with a clear sky view directly above. The signal is able to penetrate plastic and terracotta planters and a thin layer of soil, but may struggle if the soil layer is too thick. These nodes will not start recording without attaining a GPS lock and repeated attempts will excessively drain the battery.
63 63  
64 64  === **4- Visibility and Location Marking** ===
65 65  
... ... @@ -82,10 +82,12 @@
82 82  * **Post-Retrieval Charging**:
83 83  ** After retrieval, charge the instruments to about 50-60% (indicated as "orange" level) unless they are to be immediately re-deployed.
84 84  * **Storage and Shipping Charge Level**:
85 -** Maintain a battery charge level of around 50-60% (e.g. "orange") for both storage and shipping purposes.
86 +** Maintain a battery charge level of around 50-60% for both storage and shipping purposes.
86 86  ** This charge level is recommended to prevent battery damage and is safe for transportation.
87 87  ** Nodes should not be stored fully charged, and it **they should especially not be stored with 0 charge.**
88 88  
90 +=== ===
91 +
89 89  (((
90 90  === **6- Data Sharing and Metadata Creation** ===
91 91  )))
... ... @@ -92,11 +92,13 @@
92 92  
93 93  **GPS Data**:
94 94  
95 -* Ensure you have documented precise lat/lon locations for each station and **DOCUMENTED THIS CAREFULLY**
98 +* Download the GPS file to a laptop. (???)
99 +* Share this file on a drive accessible to all team members for uniform understanding of node locations.
96 96  
97 97  **Photo Sharing**:
98 98  
99 -* It is strongly encouraged to take pictures of each site and upload these to a shared platform (OneDrive, Dropbox, etc.).
103 +* Upload site photos to a shared platform (OneDrive, Dropbox, etc.).
104 +* Integrating photos into Google Maps or Google Earth can be particularly beneficial for easy location referencing.
100 100  
101 101  **Metadata File**:
102 102  
... ... @@ -105,7 +105,7 @@
105 105  === **7- Additional Best Practices** ===
106 106  
107 107  * **Environmental Responsibility**: Ensure that the node placement and the materials used are environmentally responsible and adhere to local regulations.
108 -* **Training and Familiarisation**: Make sure all team members are adequately trained in using the GPS devices, compass use, and other equipment to ensure consistent and accurate data collection.
113 +* **Training and Familiarisation**: Make sure all team members are adequately trained in using the GPS devices, compass, and other equipment to ensure consistent and accurate data collection.
109 109  
110 110  * (((
111 111  ==== **Keeping the Instruments Clean** ====
... ... @@ -116,12 +116,12 @@
116 116  
117 117  ----
118 118  
119 -= **Seismic Station Demobilization and Documentation** =
124 +=== **Seismic Station Demobilization and Documentation** ===
120 120  
121 121  1. (((
122 122  **Preparation for Demobilization**:
123 123  
124 -* Before starting the demobilization process, ensure you have a compass, tape, marker, pen, masking tape, clipboard, logbook, and compass ready in your tote bag.
129 +* Before starting the demobilization process, ensure you have a compass, tape, marker, pen, clipboard, logbook, and compass ready in your tote bag.
125 125  )))
126 126  1. (((
127 127  **Locating the instrument**:
... ... @@ -133,7 +133,7 @@
133 133  1. (((
134 134  **Labeling Instruments for Demobilization**:
135 135  
136 -* Write the station name and the instrument’s serial number on a masking tape label to apply to the top of the node.
141 +* Write the station name and the instrument’s serial number on a label.
137 137  * Add markers 'D' (for download), 'C' (for charge), and ‘R’ (for removal) next to checkboxes on the label.
138 138  * Affix this label to the top of the instrument to avoid confusion during the charging and downloading data.
139 139  )))
... ... @@ -162,31 +162,39 @@
162 162  
163 163  ----
164 164  
165 -= **Charging Procedure for Seismic Nodes** =
170 +=== **Charging Procedure for Seismic Nodes** ===
166 166  
167 167  1. (((
168 -=== **Preparation for Charging**: ===
173 +**Preparation for Charging**:
169 169  
170 170  * Before charging, ensure each node is clean. This involves removing any dirt or debris to maintain the integrity of the equipment and ensure effective charging.
176 +
177 +
171 171  )))
172 172  1. (((
173 -=== **Disassembling the Node**: ===
180 +**Disassembling the Node**:
174 174  
175 175  * For the IGU-16HR, remove the battery (bottom half) from the sensor. This is done by unscrewing the spikes counter-clockwise.
183 +
184 +
176 176  )))
177 177  1. (((
178 -=== **Setting Nodes in the Charging Box**: ===
187 +**Setting Nodes in the Charging Box**:
179 179  
180 180  * Place 1-16 IGU-16HR battery components upside-down into the charger, assuring they are oriented properly.
190 +
191 +
181 181  )))
182 182  1. (((
183 -=== **Monitoring the Charging Process**: ===
194 +**Monitoring the Charging Process**:
184 184  
185 185  * Once the nodes are set in the charging box and the charging process begins, lights adjacent to the batteries will illuminate. These lights indicate that charging is underway.
186 186  * Observe the transition of the lights from steady red to orange, then to green, and finally to flashing green. A flashing green light signifies that the batteries are fully charged. For storage, the goal is to charge them to ORANGE.
198 +
199 +
187 187  )))
188 188  1. (((
189 -=== **Updating Charge Status**: ===
202 +**Updating Charge Status**:
190 190  
191 191  * During the charging period, take this opportunity to update the status of each unit. Check the //"C"// box on your temporary labels to indicate that the unit has been successfully charged.
192 192  * This step is crucial for tracking the charging status of multiple units, especially when handling a large number of nodes.
... ... @@ -303,7 +303,9 @@
303 303  
304 304  **Procedure for Seismic Nodes:**
305 305  
306 -* If the nodes are placed in a sturdy plastic bag at the time of installation, the cleaning procedure should be straightforward. If not you have a lot of work to do before they are returned to us!
319 +* If the nodes are placed in a thick plastic bag at the time of installation, the cleaning procedure should be straightforward. If not you have a lot of work to do before they are returned to us!
320 +
321 += =
307 307  )))
308 308  
309 309  (% class="col-xs-12 col-sm-4" %)
... ... @@ -312,11 +312,24 @@
312 312  (((
313 313  **Contents**
314 314  
315 -{{toc/}}
316 -
317 -
330 +(% class="wikitoc" %)
331 +* [[SmartSolo IGU 16HR 3C (5 Hz) Short Period Node>>path:#HSmartSoloIGU16HR3C285Hz29ShortPeriodNode]]
332 +** [[Sub-paragraph>>path:#HSub-paragraph]]
333 +** [[ >>path:#H]]
334 +* [[Smart Solo BD3C-5 (5 second) Broad-Band Node>>path:#HSmartSoloBD3C-5285second29Broad-BandNode]]
335 +** [[GPS Considerations>>path:#HGPSConsiderations]]
336 +* [[Keeping the Instruments Clean>>path:#HKeepingtheInstrumentsClean]]
337 +* [[Charge Time, Instrument Life, and Charge During Storage & Shipping>>path:#HChargeTime2CInstrumentLife2CandChargeDuringStorage26Shipping]]
338 +* [[Best Practices and Guide>>path:#HBestPracticesandGuide]]
339 +** [[Install>>path:#HInstall]]
340 +** [[Removing/Demob>>path:#HRemoving2FDemob]]
341 +** [[Charging>>path:#HCharging]]
342 +** [[Downloading and Converting Data to MiniSeed>>path:#HDownloadingandConvertingDatatoMiniSeed]]
343 +** [[Converting data>>path:#HConvertingdata]]
344 +** [[Cleaning>>path:#HCleaning]]
318 318  )))
319 319  
347 +
320 320  (% class="box" %)
321 321  (((
322 322  = SmartSolo [[BD3C-5>>url:https://smartsolo.com/cp-4.html]] =