Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/06/16 07:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,21 +2,22 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -= **Node Types** = 5 += **SmartSolo Node Types and Procedures** = 6 6 7 - ANSIR carrytwotypesof three-channel nodes7 +**SmartSolo Node Variants:** 8 8 9 -* **SmartSolo IGU 16HR 3C (5 Hz Short Period )**10 -* **SmartSolo BD3C-5 (5-second Broad-Band )**9 +* **SmartSolo IGU 16HR 3C (5 Hz) Short Period Node** 10 +* **SmartSolo BD3C-5 (5-second) Broad-Band Node** 11 11 12 - Bothhavea battery capacityof around30days. Theprogramming,operation, and downloading procedures for both types of SmartSolo nodes are alsosimilar.12 +The installation, demobilization, and data downloading procedures for both types of SmartSolo nodes – the IGU 16HR 3C Short Period Node and the BD3C-5 Broad-Band Node – are largely similar. 13 13 14 +This uniformity in process ensures ease of operation across different node types, allowing for a streamlined approach in fieldwork and data management. 14 14 15 15 ---- 16 16 17 -= ** ProgrammingDefaults** =18 += **Node Setup** = 18 18 19 - ANU recommendsthattheSP 16HR-3Cbe set toagain of 24dbnd no higherthan 250 Hz samplingrate. The BD3C-5 shouldbe set to a gainf 6db (maximum allowed). Thesearewhat we usefor our internalexperiments.**Note that thisgainmust be removed when exporting to miniseed,**otherwiseamplitudes willbe either15.84893192(24db)or2 (6db)toohigh. Wealso recommend disabling bluetoothtoincrease batterypower, and to enable "FIFO" mode justin caseolddatais still present on the unitsandyou run out of space (although it is VERY unlikely you will go over64Gb forone deploy). If usingthe"timed turnon" option, pleasebeawarethat**the unitswillnot beginrecording until they haveacquireda GPS lock**,which maynoroccurifthey are buriedtoodeeply or have very poor sky view.20 +Short term (~~30 day) battery powered nodes. The default gain should typically be set to 24 db for the Short Period 16HR-3C and 6 db for the Broadband BD3C-5. **This gain must be removed when exporting to miniseed.** 20 20 21 21 22 22 == **Pre-Fieldwork Preparation** == ... ... @@ -48,7 +48,7 @@ 48 48 === **2- Node Placement** === 49 49 ))) 50 50 51 -**Protection**: Place nodes inside (landfill)biodegradable bagstominimizecleaningandcross-site soilcontamination.52 +**Protection**: Place nodes inside thick, landfill biodegradable plastic bags for environmental protection and to minimize cleaning. 52 52 53 53 **Site Analysis**: 54 54