Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/06/16 07:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,9 +14,9 @@ 14 14 15 15 ---- 16 16 17 -= ** NodeSetup** =17 += **Programming Defaults** = 18 18 19 - Short term(~~30day)batterypowered nodes. Thedefault gain should typicallybesetto24for theShortPeriod16HR-3Cand 6db for theBroadbandBD3C-5.**Thisgainmust be removed whenexportingtominiseed.**19 +ANU recommends that the SP 16HR-3C be set to a gain of 24db and no higher than 250 Hz sampling rate. The BD3C-5 should be set to a gain of 6db (maximum allowed). These are what we use for our internal experiments. **Note that this gain must be removed when exporting to miniseed, **otherwise amplitudes will be either 15.84893192 (24db) or 2 (6db) too high. We also recommend disabling bluetooth to increase battery power, and to enable "FIFO" mode just in case old data is still present on the units and you run out of space (although it is VERY unlikely you will go over 64 Gb for one deploy). If using the "timed turnon" option, please be aware that **the units will not begin recording until they have acquired a GPS lock**, which may nor occur if they are buried too deeply or have very poor sky view. 20 20 21 21 22 22 == **Pre-Fieldwork Preparation** ==