Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/07/16 16:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,22 +2,21 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -= ** SmartSoloNode Typesand Procedures** =5 += **Node Types** = 6 6 7 - **SmartSoloNodeVariants:**7 +ANSIR carry two types of three-channel nodes 8 8 9 -* **SmartSolo IGU 16HR 3C (5 Hz )Short PeriodNode**10 -* **SmartSolo BD3C-5 (5 -second)Broad-BandNode**9 +* **SmartSolo IGU 16HR 3C (5 Hz Short Period)** 10 +* **SmartSolo BD3C-5 (5 Second Broad-Band)** 11 11 12 - Theinstallation,demobilization, and data downloading procedures for both types of SmartSolo nodes– the IGU 16HR 3C Short Period Nodeand the BD3C-5 Broad-Band Node–arelargelysimilar.12 +Both have a battery capacity of around 30 days. The programming, operation, and downloading procedures for both types of SmartSolo nodes are also similar. 13 13 14 -This uniformity in process ensures ease of operation across different node types, allowing for a streamlined approach in fieldwork and data management. 15 15 16 16 ---- 17 17 18 -= ** NodeSetup** =17 += **Programming Defaults** = 19 19 20 - Short term(~~30day)batterypowered nodes. Thedefault gain should typicallybesetto24 dbfor theShortPeriod16HR-3Cand 6db for theBroadbandBD3C-5.**Thisgainmust be removed whenexportingtominiseed.**19 +ANU recommends that the SP 16HR-3C be set to a gain of 24db and no higher than 250 Hz sampling rate. The BD3C-5 should be set to a gain of 6db (maximum allowed). These are what we use for our internal experiments. **Note that this gain must be removed when exporting to miniseed, **otherwise amplitudes will be a factor of either 15.84893192 (24db) or 2 (6db) too high. We also recommend disabling bluetooth to increase battery life, and to enable "FIFO" mode just in case old data is still present on the units and you run out of space (although it is unlikely you will go over 64 Gb for one deploy). If using the "timed turn-on" option, please be aware that **the units will not begin recording until they have acquired a GPS lock**, which may nor occur if they are buried too deeply or have very poor sky view. 21 21 22 22 23 23 == **Pre-Fieldwork Preparation** == ... ... @@ -28,7 +28,7 @@ 28 28 ((( 29 29 **INVEST IN FAST EXTERNAL HARD DRIVES – DO NOT LET THIS BE THE LIMITATION OF DATA HARVESTING** 30 30 31 -**Assume ~~1 Tb of storage for both raw and exported data per 50 nodes @ 250 Hz & 30 days** 30 +**Assume ~~1 Tb of storage for both raw and exported data per 50 nodes @ 250 Hz & 30 days. One node recording at 250 Hz for 30 days tends to create about 3 Gb of miniseed data.** 32 32 ))) 33 33 ))) 34 34 ... ... @@ -49,7 +49,7 @@ 49 49 === **2- Node Placement** === 50 50 ))) 51 51 52 -**Protection**: Place nodes inside thick,landfill biodegradableplasticbagsforenvironmentalprotection andtominimizecleaning.51 +**Protection**: Place nodes inside (landfill) biodegradable bags to minimize cleaning and cross-site soil contamination. 53 53 54 54 **Site Analysis**: 55 55 ... ... @@ -328,10 +328,7 @@ 328 328 **Contents** 329 329 330 330 (% class="wikitoc" %) 331 -* [[SmartSolo IGU 16HR 3C (5 Hz) Short Period Node>>path:#HSmartSoloIGU16HR3C285Hz29ShortPeriodNode]] 332 -** [[Sub-paragraph>>path:#HSub-paragraph]] 333 -** [[ >>path:#H]] 334 -* [[Smart Solo BD3C-5 (5 second) Broad-Band Node>>path:#HSmartSoloBD3C-5285second29Broad-BandNode]] 330 +* [[Smart Solo BD3C-5 (5 second) B>>path:#HSmartSoloBD3C-5285second29Broad-BandNode]] 335 335 ** [[GPS Considerations>>path:#HGPSConsiderations]] 336 336 * [[Keeping the Instruments Clean>>path:#HKeepingtheInstrumentsClean]] 337 337 * [[Charge Time, Instrument Life, and Charge During Storage & Shipping>>path:#HChargeTime2CInstrumentLife2CandChargeDuringStorage26Shipping]]