Changes for page SmartSolo Seismometers

Last modified by Kimberley on 2025/05/26 13:10

From version 42.2
edited by robert
on 2024/03/25 12:59
Change comment: There is no comment for this version
To version 42.3
edited by robert
on 2024/05/14 13:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,16 +2,15 @@
2 2  (((
3 3  (% class="col-xs-12 col-sm-8" %)
4 4  (((
5 -= **SmartSolo Node Types and Procedures** =
5 += **Node Types** =
6 6  
7 -**SmartSolo Node Variants:**
7 +ANSIR carry two types of three-channel nodes
8 8  
9 -* **SmartSolo IGU 16HR 3C (5 Hz) Short Period Node**
10 -* **SmartSolo BD3C-5 (5-second) Broad-Band Node**
9 +* **SmartSolo IGU 16HR 3C (5 Hz Short Period)**
10 +* **SmartSolo BD3C-5 (5-second Broad-Band)**
11 11  
12 -The installation, demobilization, and data downloading procedures for both types of SmartSolo nodes – the IGU 16HR 3C Short Period Node and the BD3C-5 Broad-Band Node are largely similar.
12 +Both have a battery capacity of around 30 days. The programming, operation, and downloading procedures for both types of SmartSolo nodes are also similar.
13 13  
14 -This uniformity in process ensures ease of operation across different node types, allowing for a streamlined approach in fieldwork and data management.
15 15  
16 16  ----
17 17  
... ... @@ -49,7 +49,7 @@
49 49  === **2- Node Placement** ===
50 50  )))
51 51  
52 -**Protection**: Place nodes inside thick, landfill biodegradable plastic bags for environmental protection and to minimize cleaning.
51 +**Protection**: Place nodes inside (landfill) biodegradable bags to minimize cleaning and cross-site soil contamination.
53 53  
54 54  **Site Analysis**:
55 55