Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/06/16 07:51
From version 39.1
edited by Sima Mousavi
on 2024/01/25 14:49
on 2024/01/25 14:49
Change comment:
There is no comment for this version
To version 34.2
edited by Sima Mousavi
on 2024/01/24 17:41
on 2024/01/24 17:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,19 +2,6 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -= **SmartSolo Node Types and Procedures** = 6 - 7 -**SmartSolo Node Variants:** 8 - 9 -* **SmartSolo IGU 16HR 3C (5 Hz) Short Period Node** 10 -* **SmartSolo BD3C-5 (5-second) Broad-Band Node** 11 - 12 -The installation, demobilization, and data downloading procedures for both types of SmartSolo nodes – the IGU 16HR 3C Short Period Node and the BD3C-5 Broad-Band Node – are largely similar. 13 - 14 -This uniformity in process ensures ease of operation across different node types, allowing for a streamlined approach in fieldwork and data management. 15 - 16 ----- 17 - 18 18 = **Node Setup** = 19 19 20 20 Short term (~~30 day) battery powered nodes. The default gain should be 24 db for the 16HR-3C and 6 db for the BD3C-5 ... ... @@ -162,12 +162,8 @@ 162 162 163 163 * Before physically removing the instrument, double-check that all necessary data has been downloaded and all photos and notes have been taken. 164 164 * Carefully dismantle and pack the equipment, ensuring that all components are accounted for and securely stored for transport. 165 - 166 - 167 167 ))) 168 168 169 -[[image:1706153556166-231.jpeg||data-xwiki-image-style-alignment="center" height="345" width="460"]] 170 - 171 171 ---- 172 172 173 173 === **Charging Procedure for Seismic Nodes** === ... ... @@ -200,13 +200,6 @@ 200 200 * This step is crucial for tracking the charging status of multiple units, especially when handling a large number of nodes. 201 201 ))) 202 202 203 -[[IGU 16-HRcharger (left) and harvester (right)>>image:1705195933422-337.png||data-xwiki-image-style-alignment="center" height="299" width="530"]] 204 - 205 - 206 - 207 - 208 -[[image:1706153354750-415.png||data-xwiki-image-style-alignment="center" height="317" width="562"]] 209 - 210 210 ---- 211 211 212 212 === **Downloading and Converting Seismic Data to MiniSeed Format** === ... ... @@ -249,6 +249,7 @@ 249 249 ((( 250 250 * **Ensure to export data as "COUNTS", not "mV".** 251 251 228 + 252 252 * **Set "Remove Gain" to the same decibel gain as during programming (ANU usually sets this to 18 db, but double-check).** 253 253 ))) 254 254 ))) ... ... @@ -263,7 +263,7 @@ 263 263 * Be cautious: if the laptop enters sleep mode, the download will pause. 264 264 ))) 265 265 1. ((( 266 - //**Investment in Storage Hardware**~://243 +**Investment in Storage Hardware**: 267 267 268 268 * (% class="box warningmessage" %) 269 269 ((( ... ... @@ -282,39 +282,8 @@ 282 282 **Finalizing the Download**: 283 283 284 284 * After downloading, mark the //"D"// box on your temporary labels to indicate completion. 285 - 286 - 287 287 ))) 288 288 289 -[[image:1706153266647-145.png||data-xwiki-image-style-alignment="center" height="340" width="603"]] 290 - 291 - 292 - 293 -[[Caption>>image:1705195543887-977.png||data-xwiki-image-style-alignment="center" height="534" width="632"]] 294 - 295 - 296 - 297 - 298 -[[Caption>>image:1705195543890-537.png||data-xwiki-image-style-alignment="center" height="397" width="665"]] 299 - 300 - 301 - 302 -[[Caption>>image:1705195543891-334.png||data-xwiki-image-style-alignment="center" height="379" width="650"]] 303 - 304 - 305 - 306 -[[image:1705195543898-365.png||data-xwiki-image-style-alignment="center" height="467" width="674"]] 307 - 308 ----- 309 - 310 -=== **Cleaning** === 311 - 312 -**Procedure for Seismic Nodes:** 313 - 314 -* If the nodes are placed in a thick plastic bag at the time of installation, the cleaning procedure should be straightforward. If not you have a lot of work to do before they are returned to us! 315 - 316 -= = 317 - 318 318 = SmartSolo IGU 16HR 3C (5 Hz) Short Period Node = 319 319 320 320 blahblah ... ... @@ -322,7 +322,7 @@ 322 322 == Sub-paragraph == 323 323 324 324 325 -== [[image:1705196270090-364.png]]==271 +== == 326 326 327 327 328 328 = Smart Solo BD3C-5 (5 second) Broad-Band Node = ... ... @@ -329,7 +329,9 @@ 329 329 330 330 Lorem 331 331 278 +[[image:1705196270090-364.png]] 332 332 280 + 333 333 == GPS Considerations == 334 334 335 335 The GPS antenna is at the top and center of the unit, and will (usually) only receive signal with a clear sky view directly above. The signal is able to penetrate plastic and terracotta planters and a thin layer of soil, but may struggle if the soil layer is too thick. The BD3C will not start recording without first attaining a GPS lock. ... ... @@ -413,9 +413,7 @@ 413 413 414 414 Use existing field logbook to note time, SN and station name plus any notes – including any issues with orientation or level or anything else 415 415 416 -[[IGU 16-HRcharger (left) and harvester (right)>>image:1705195933422-337.png||data-xwiki-image-style-alignment="center"]] 417 417 418 - 419 419 == Charging == 420 420 421 421 Clean node prior to charging and harvesting the data ... ... @@ -428,8 +428,10 @@ 428 428 429 429 This is a good time to check the "C" box on your temporary labels to mark that the unit has been charged 430 430 377 +[[IGU 16-HRcharger (left) and harvester (right)>>image:1705195933422-337.png||data-xwiki-image-style-alignment="center"]] 431 431 432 432 380 + 433 433 == Downloading and Converting Data to MiniSeed == 434 434 435 435
- 1706153266647-145.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.sima - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.7 MB - Content
- 1706153354750-415.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.sima - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.1 MB - Content
- 1706153556166-231.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.sima - Size
-
... ... @@ -1,1 +1,0 @@ 1 -839.4 KB - Content