Changes for page SmartSolo Node Seismometers
Last modified by robert on 2025/08/21 13:08
From version 35.1
edited by Sima Mousavi
on 2024/01/24 17:44
on 2024/01/24 17:44
Change comment:
There is no comment for this version
To version 40.1
edited by Sima Mousavi
on 2024/01/25 14:53
on 2024/01/25 14:53
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,6 +2,19 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 += **SmartSolo Node Types and Procedures** = 6 + 7 +**SmartSolo Node Variants:** 8 + 9 +* **SmartSolo IGU 16HR 3C (5 Hz) Short Period Node** 10 +* **SmartSolo BD3C-5 (5-second) Broad-Band Node** 11 + 12 +The installation, demobilization, and data downloading procedures for both types of SmartSolo nodes – the IGU 16HR 3C Short Period Node and the BD3C-5 Broad-Band Node – are largely similar. 13 + 14 +This uniformity in process ensures ease of operation across different node types, allowing for a streamlined approach in fieldwork and data management. 15 + 16 +---- 17 + 5 5 = **Node Setup** = 6 6 7 7 Short term (~~30 day) battery powered nodes. The default gain should be 24 db for the 16HR-3C and 6 db for the BD3C-5 ... ... @@ -149,8 +149,12 @@ 149 149 150 150 * Before physically removing the instrument, double-check that all necessary data has been downloaded and all photos and notes have been taken. 151 151 * Carefully dismantle and pack the equipment, ensuring that all components are accounted for and securely stored for transport. 165 + 166 + 152 152 ))) 153 153 169 +[[image:1706153556166-231.jpeg||data-xwiki-image-style-alignment="center" height="345" width="460"]] 170 + 154 154 ---- 155 155 156 156 === **Charging Procedure for Seismic Nodes** === ... ... @@ -183,7 +183,13 @@ 183 183 * This step is crucial for tracking the charging status of multiple units, especially when handling a large number of nodes. 184 184 ))) 185 185 203 +[[IGU 16-HRcharger (left) and harvester (right)>>image:1705195933422-337.png||data-xwiki-image-style-alignment="center" height="299" width="530"]] 186 186 205 + 206 + 207 + 208 +[[image:1706153354750-415.png||data-xwiki-image-style-alignment="center" height="317" width="562"]] 209 + 187 187 ---- 188 188 189 189 === **Downloading and Converting Seismic Data to MiniSeed Format** === ... ... @@ -226,7 +226,6 @@ 226 226 ((( 227 227 * **Ensure to export data as "COUNTS", not "mV".** 228 228 229 - 230 230 * **Set "Remove Gain" to the same decibel gain as during programming (ANU usually sets this to 18 db, but double-check).** 231 231 ))) 232 232 ))) ... ... @@ -260,8 +260,63 @@ 260 260 **Finalizing the Download**: 261 261 262 262 * After downloading, mark the //"D"// box on your temporary labels to indicate completion. 285 + 286 + 263 263 ))) 264 264 289 +[[image:1706153266647-145.png||data-xwiki-image-style-alignment="center" height="340" width="603"]] 290 + 291 + 292 + 293 +[[Caption>>image:1705195543887-977.png||data-xwiki-image-style-alignment="center" height="534" width="632"]] 294 + 295 + 296 + 297 + 298 +[[Caption>>image:1705195543890-537.png||data-xwiki-image-style-alignment="center" height="397" width="665"]] 299 + 300 + 301 + 302 +[[Caption>>image:1705195543891-334.png||data-xwiki-image-style-alignment="center" height="379" width="650"]] 303 + 304 + 305 + 306 +[[image:1705195543898-365.png||data-xwiki-image-style-alignment="center" height="467" width="674"]] 307 + 308 +---- 309 + 310 +=== **Cleaning** === 311 + 312 +**Procedure for Seismic Nodes:** 313 + 314 +* If the nodes are placed in a thick plastic bag at the time of installation, the cleaning procedure should be straightforward. If not you have a lot of work to do before they are returned to us! 315 + 316 += = 317 + 318 += = 319 + 320 += = 321 + 322 += = 323 + 324 += = 325 + 326 += = 327 + 328 += = 329 + 330 += **~=~=~=~=~=~=~=~=~=~=Done! Should be deleted from here~=~=~=~=~=~=~=~=~=~=~=** = 331 + 332 += = 333 + 334 += = 335 + 336 += = 337 + 338 += = 339 + 340 += = 341 + 265 265 = SmartSolo IGU 16HR 3C (5 Hz) Short Period Node = 266 266 267 267 blahblah ... ... @@ -360,7 +360,9 @@ 360 360 361 361 Use existing field logbook to note time, SN and station name plus any notes – including any issues with orientation or level or anything else 362 362 440 +[[IGU 16-HRcharger (left) and harvester (right)>>image:1705195933422-337.png||data-xwiki-image-style-alignment="center"]] 363 363 442 + 364 364 == Charging == 365 365 366 366 Clean node prior to charging and harvesting the data ... ... @@ -373,10 +373,8 @@ 373 373 374 374 This is a good time to check the "C" box on your temporary labels to mark that the unit has been charged 375 375 376 -[[IGU 16-HRcharger (left) and harvester (right)>>image:1705195933422-337.png||data-xwiki-image-style-alignment="center"]] 377 377 378 378 379 - 380 380 == Downloading and Converting Data to MiniSeed == 381 381 382 382
- 1706153266647-145.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.sima - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.7 MB - Content
- 1706153354750-415.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.sima - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.1 MB - Content
- 1706153556166-231.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.sima - Size
-
... ... @@ -1,0 +1,1 @@ 1 +839.4 KB - Content