Changes for page SmartSolo Seismometers
Last modified by Kimberley on 2025/05/26 13:10
From version 35.1
edited by Sima Mousavi
on 2024/01/24 17:44
on 2024/01/24 17:44
Change comment:
There is no comment for this version
To version 36.1
edited by Sima Mousavi
on 2024/01/24 17:50
on 2024/01/24 17:50
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -183,7 +183,6 @@ 183 183 * This step is crucial for tracking the charging status of multiple units, especially when handling a large number of nodes. 184 184 ))) 185 185 186 - 187 187 ---- 188 188 189 189 === **Downloading and Converting Seismic Data to MiniSeed Format** === ... ... @@ -226,7 +226,6 @@ 226 226 ((( 227 227 * **Ensure to export data as "COUNTS", not "mV".** 228 228 229 - 230 230 * **Set "Remove Gain" to the same decibel gain as during programming (ANU usually sets this to 18 db, but double-check).** 231 231 ))) 232 232 ))) ... ... @@ -260,8 +260,21 @@ 260 260 **Finalizing the Download**: 261 261 262 262 * After downloading, mark the //"D"// box on your temporary labels to indicate completion. 261 + 262 + 263 + 263 263 ))) 264 264 266 +---- 267 + 268 +=== **Cleaning** === 269 + 270 +**Procedure for Seismic Nodes:** 271 + 272 +* If the nodes are placed in a thick plastic bag at the time of installation, the cleaning procedure should be straightforward. If not you have a lot of work to do before they are returned to us! 273 + 274 += = 275 + 265 265 = SmartSolo IGU 16HR 3C (5 Hz) Short Period Node = 266 266 267 267 blahblah