Last modified by robert on 2025/06/16 07:51

From version 24.1
edited by Sima Mousavi
on 2024/01/24 16:27
Change comment: There is no comment for this version
To version 22.1
edited by robert
on 2024/01/23 12:51
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.sima
1 +XWiki.robert
Content
... ... @@ -4,11 +4,8 @@
4 4  (((
5 5  = **Node Setup** =
6 6  
7 -Short term (~~30 day) battery powered nodes. The default gain should be 24 db for the 16HR-3C and 6 db for the BD3C-5
7 +Short term (~~30 day) battery powered nodes
8 8  
9 -
10 -~*~**this needs to be reformatted
11 -
12 12  == **Pre-Fieldwork Preparation** ==
13 13  
14 14  (% class="box infomessage" %)
... ... @@ -79,6 +79,8 @@
79 79  
80 80  === ===
81 81  
79 +=== ===
80 +
82 82  === **6- Data Sharing and Metadata Creation** ===
83 83  
84 84  **GPS Data**:
... ... @@ -109,60 +109,6 @@
109 109  
110 110  = =
111 111  
112 -=== **Seismic Station Demobilization and Documentation** ===
113 -
114 -1. (((
115 -**Preparation for Demobilization**:
116 -
117 -* Before starting the demobilization process, ensure you have a compass, tape, marker, pen, clipboard, logbook, and compass ready in your tote bag.
118 -)))
119 -1. (((
120 -**Locating the instrument**:
121 -
122 -* Use the downloaded GPS file to accurately locate the node for demobilization.
123 -* Import this KMZ file onto your phone for easy reference and location tracking.
124 -* Utilize Google Maps or Google Earth to create a KMZ file of the station’s location.
125 -)))
126 -1. (((
127 -**Labeling Instruments for Demobilization**:
128 -
129 -* Write the station name and the instrument’s serial number on a label.
130 -* Add markers 'D' (for download), 'C' (for charge), and ‘R’ (for removal) next to checkboxes on the label.
131 -* Affix this label to the top of the instrument to avoid confusion during the charging and downloading data.
132 -)))
133 -1. (((
134 -**Photographing the Setup Node**:
135 -
136 -* Take a photo of the entire setup node with the __//label//__ and __//compass visible//__.
137 -* This photo serves as a final record of the instrument’s condition and orientation at the time of removal.
138 -)))
139 -1. (((
140 -**Logging Demobilization Details**:
141 -
142 -* Use the field logbook to note the time of demobilization, serial numbers, and station name.
143 -* Record any observations or issues related to the instrument’s orientation, level, or any other relevant factors.
144 -)))
145 -1. (((
146 -**Final Checks and Equipment Removal**:
147 -
148 -* Before physically removing the instrument, double-check that all necessary data has been downloaded and all photos and notes have been taken.
149 -* Carefully dismantle and pack the equipment, ensuring that all components are accounted for and securely stored for transport.
150 -)))
151 -
152 -
153 -
154 -
155 -
156 -
157 -
158 -
159 -
160 -
161 -
162 -
163 -
164 -
165 -
166 166  = SmartSolo IGU 16HR 3C (5 Hz) Short Period Node =
167 167  
168 168  blahblah