... ... @@ -435,10 +435,8 @@
435 435  
436 436  == IGU 16-1C ==
437 437  
438 -The 1C nodes seem to have the same response as the 3-channel IGU-16HR-3C (above), however the response posted at IRIS-NRL seems to imply that there is no poles and zeros information (e.g. a flat/linear response). This is 100% not so.
438 +The 1C nodes seem to have a slightly different response to the 3C, but the 3C version seems to fit a lot better than the version published at IRIS-NRL which has no PAZ information. We are looking into this.
439 439  
440 -[[IGU-16 1C, X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter. Seems to be same response as IGU-16HR-3C.>>image:IGU16_1C_Z_huddle.png]]
441 -
442 442  == BD3C-5 ==
443 443  
444 444   'BD3C': {'poles':[(-1720.4+0j), (-1.2+0.9j), (-1.2-0.9j)],
... ... @@ -453,6 +453,8 @@
453 453  (% class="wikigeneratedid" %)
454 454  Below the corner frequency 0.2 Hz (i.e. 5 seconds) the response still does a good job, but may need to be dialed in a bit. We are looking into this.
455 455  
454 +(% class="wikigeneratedid" %)
455 +
456 456  
457 457  [[BD3C 0.1 to 5 Hz bandpass>>image:BD3C_Z_huddle.0.1.png]]
458 458  
... ... @@ -460,7 +460,7 @@
460 460  
461 461  == IGU-16 Horizontal noise & how to avoid ==
462 462  
463 -The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz.
463 +The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz.
464 464  
465 465  [[IGU-16HR-3C Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo. The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]]
466 466  
IGU16_1C_Z_huddle.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.robert
Size
... ... @@ -1,1 +1,0 @@
1 -72.3 KB
Content