Changes for page SmartSolo Node Seismometers
Last modified by robert on 2026/02/27 19:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -435,8 +435,10 @@ 435 435 436 436 == IGU 16-1C == 437 437 438 -The 1C nodes seem to have a slightlydifferentresponsetothe 3C, but the 3C versionseems tofit a lot better than theversion published at IRIS-NRLwhichhas noPAZinformation.We arelookingintothis.438 +The 1C nodes seem to have the same response as the 3-channel IGU-16HR-3C (above), however the response posted at IRIS-NRL seems to imply that there is no poles and zeros information (e.g. a flat/linear response). This is 100% not so. 439 439 440 +[[IGU-16 1C, X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter. Seems to be same response as IGU-16HR-3C.>>image:IGU16_1C_Z_huddle.png]] 441 + 440 440 == BD3C-5 == 441 441 442 442 'BD3C': {'poles':[(-1720.4+0j), (-1.2+0.9j), (-1.2-0.9j)], ... ... @@ -451,8 +451,6 @@ 451 451 (% class="wikigeneratedid" %) 452 452 Below the corner frequency 0.2 Hz (i.e. 5 seconds) the response still does a good job, but may need to be dialed in a bit. We are looking into this. 453 453 454 -(% class="wikigeneratedid" %) 455 - 456 456 457 457 [[BD3C 0.1 to 5 Hz bandpass>>image:BD3C_Z_huddle.0.1.png]] 458 458 ... ... @@ -460,7 +460,7 @@ 460 460 461 461 == IGU-16 Horizontal noise & how to avoid == 462 462 463 -The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz.463 +The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz. 464 464 465 465 [[IGU-16HR-3C Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo. The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]] 466 466
- IGU16_1C_Z_huddle.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +72.3 KB - Content