Changes for page SmartSolo Node Seismometers
Last modified by robert on 2026/02/27 19:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (2 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -431,12 +431,14 @@ 431 431 432 432 [[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:IGU16_Z_huddle.png]] 433 433 434 -[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:IGU16_N_huddle.png]] 434 +[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz bandpass filter>>image:IGU16_N_huddle.png]] 435 435 436 436 == IGU 16-1C == 437 437 438 -The 1C nodes seem to have a s lightlydifferent response to the3C(TBA)438 +The 1C nodes seem to have the same response as the 3-channel IGU-16HR-3C (above), however the response posted at IRIS-NRL seems to imply that there is no poles and zeros information (e.g. a flat/linear response). This is 100% not so. 439 439 440 +[[IGU-16 1C, X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz bandpass filter. Seems to be same response as IGU-16HR-3C.>>image:IGU16_1C_Z_huddle.png]] 441 + 440 440 == BD3C-5 == 441 441 442 442 'BD3C': {'poles':[(-1720.4+0j), (-1.2+0.9j), (-1.2-0.9j)], ... ... @@ -446,11 +446,19 @@ 446 446 447 447 [[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:BD3C_Z_huddle.png]] 448 448 449 -[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:BD3C_N_huddle.png]] 451 +[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz bandpass filter>>image:BD3C_N_huddle.png]] 450 450 453 +(% class="wikigeneratedid" %) 454 +Below the corner frequency 0.2 Hz (i.e. 5 seconds) the response still does a good job, but may need to be dialed in a bit. We are looking into this. 455 + 456 + 457 +[[BD3C **0.1 **to 5 Hz bandpass filter>>image:BD3C_Z_huddle.0.1.png]] 458 + 459 +[[BD3C **0.1** to 5 Hz bandpass filter>>image:BD3C_N_huddle.0.1.png]] 460 + 451 451 == IGU-16 Horizontal noise & how to avoid == 452 452 453 -The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz.463 +The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz. 454 454 455 455 [[IGU-16HR-3C Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo. The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]] 456 456
- BD3C_N_huddle.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -7 3.3KB1 +72.1 KB - Content
- BD3C_Z_huddle.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 64.6KB1 +52.1 KB - Content
- BD3C_N_huddle.0.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +72.1 KB - Content
- BD3C_Z_huddle.0.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.1 KB - Content
- IGU16_1C_Z_huddle.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +72.3 KB - Content