Changes for page SmartSolo Node Seismometers
Last modified by robert on 2026/02/27 19:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -435,7 +435,7 @@ 435 435 436 436 == IGU 16-1C == 437 437 438 -The 1C nodes seem to have a slightly different response to the 3C (TBA)438 +The 1C nodes seem to have a slightly different response to the 3C, but the 3C version seems to fit a lot better than the version published at IRIS-NRL which has no PAZ information. We are looking into this. 439 439 440 440 == BD3C-5 == 441 441 ... ... @@ -444,14 +444,31 @@ 444 444 'gain':1.69726e-05, 445 445 'sensitivity': 702651512.6046528} 446 446 447 - *imageTBAbuttheyhavebeencreatedinthepast~-~-we are 100%confidentourpublishedresponses are correct447 +[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:BD3C_Z_huddle.png]] 448 448 449 - ==Horizontalnoise&howtoavoid==449 +[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:BD3C_N_huddle.png]] 450 450 451 -The 5 Hz nodes are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz. 451 +(% class="wikigeneratedid" %) 452 +Below the corner frequency 0.2 Hz (i.e. 5 seconds) the response still does a good job, but may need to be dialed in a bit. We are looking into this. 452 452 453 -[[Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo. The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]] 454 +(% class="wikigeneratedid" %) 455 + 454 454 457 +[[BD3C 0.1 to 5 Hz bandpass>>image:BD3C_Z_huddle.0.1.png]] 458 + 459 +[[BD3C 0.1 to 5 Hz bandpass>>image:BD3C_N_huddle.0.1.png]] 460 + 461 +== IGU-16 Horizontal noise & how to avoid == 462 + 463 +The** 5 Hz nodes** are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz. 464 + 465 +[[IGU-16HR-3C Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo. The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]] 466 + 467 +(% class="wikigeneratedid" %) 468 +The BD3C-5 nodes do not have this issue: 469 + 470 +[[BD3C-5 test, as above. There is no additional noise on the horizontal channels.>>image:BD3C_psd.png]] 471 + 455 455 = **Cleaning** = 456 456 457 457 When assembled, the nodes are water resistant but not submersible. They can handle a good spray and wipe-down. A stiff plastic brush is helpful to reach areas between the metal spikes on the bottom.
- BD3C_N_huddle.0.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +72.1 KB - Content
- BD3C_N_huddle.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +72.1 KB - Content
- BD3C_Z_huddle.0.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.1 KB - Content
- BD3C_Z_huddle.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.1 KB - Content
- BD3C_psd.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +73.7 KB - Content