Changes for page SmartSolo Node Seismometers
Last modified by robert on 2026/02/27 19:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,10 +6,12 @@ 6 6 7 7 ANSIR supply two types of three-channel nodes, and one type of one-channel node: 8 8 9 -* **SmartSolo IGU 16HR 3C (5 Hz, 'very' short period)**9 +* **SmartSolo IGU-16HR 3C (5 Hz, 'very' short period)** 10 10 * **SmartSolo BD3C-5 (5 second, short period)** 11 -* **SmartSolo IGU 16 1C (5 Hz, 'very' short period, single channel)**11 +* **SmartSolo IGU-16 1C (5 Hz, 'very' short period, single channel. Not 'HR')** 12 12 13 +Visit the [[SmartSolo page>>https://smartsolo.com/igu.html]] for more detail. 14 + 13 13 The three-channel nodes have a theoretical battery capacity of ~~30 days, whereas the single-channel type has a capacity of ~~50 days. The programming, operation and downloading procedures for all types of SmartSolo nodes are also similar. 14 14 15 15 (% class="box infomessage" %) ... ... @@ -427,12 +427,14 @@ 427 427 'gain':1, 428 428 'sensitivity': 257019225.55108312} 429 429 430 -[[X axis is samples (.01 s), Y axis is velocity (m/s)>>image:IGU16_Z_huddle.png]] 432 +[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:IGU16_Z_huddle.png]] 431 431 432 -[[X axis is samples (.01 s), Y axis is velocity (m/s)>>image:IGU16_N_huddle.png]] 434 +[[X axis is samples (.01 s), Y axis is velocity (m/s), 0.5-5 Hz filter>>image:IGU16_N_huddle.png]] 433 433 434 434 == IGU 16-1C == 435 435 438 +The 1C nodes seem to have a slightly different response to the 3C (TBA) 439 + 436 436 == BD3C-5 == 437 437 438 438 'BD3C': {'poles':[(-1720.4+0j), (-1.2+0.9j), (-1.2-0.9j)], ... ... @@ -440,15 +440,17 @@ 440 440 'gain':1.69726e-05, 441 441 'sensitivity': 702651512.6046528} 442 442 447 +*image TBA but they have been created in the past~-~- we are 100% confident our published responses are correct 448 + 443 443 == Horizontal noise & how to avoid == 444 444 445 445 The 5 Hz nodes are susceptible to horizontal noise due to the placement of geophones in the units, **but this can be mitigated by completely burying the units flush with the ground.** In the below example, the node was set on the floor of our basement set on its plastic carrying case support. As such the amount of horizontal noise noticeably increases above ~~ 10Hz. 446 446 447 -[[Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo , all filtered 0.5-5Hz.The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]]453 +[[Power spectrum huddle test vs a CMG-6TD (S1) and TC120/Centaur combo. The N and E channels have excess noise above 10Hz due to "sticking up" out of the ground.>>image:IGU16_spectrum.png]] 448 448 449 449 = **Cleaning** = 450 450 451 -When assembled, the nodes are water resistant but not submersible. They can handle a good spray and wipe-down. A st rong,non-wirebrush is helpful to reach areas between the metal spikes on the bottom.457 +When assembled, the nodes are water resistant but not submersible. They can handle a good spray and wipe-down. A stiff plastic brush is helpful to reach areas between the metal spikes on the bottom. 452 452 453 453 = **Weights (for shipping)** = 454 454