Wiki source code of Seismometers

Version 31.1 by Jack Dent on 2024/12/19 14:19

Show last authors
1 (% class="row" %)
2 (((
3 (% class="col-xs-12 col-sm-8" %)
4 (((
5 = Broadband sensors =
6
7 Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.ANU LPR-200.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
8
9 == Nanometrics ==
10
11 === Trillium Compact 120 ===
12
13 === Trillium Compact Posthole 120 ===
14
15 === Trillium Compact 20 ===
16
17 === Trillum Compact Horizon ===
18
19 === ===
20
21 = Short period sensors =
22
23 Short period (SP) sensors have limited sensitivity to longer periods, but are otherwise perfectly suitable for earthquake or other high frequency analysis. They are generally defined as any instrument that begins to **lose sensitivity at periods larger that 10 seconds**. They tend to be smaller and more mechanically robust to broadband sensors.
24
25 == Lennartz Electronic LE-3D Lite (MkII) ==
26
27 etc
28
29 == Sub-paragraph ==
30
31 etc
32
33
34 == Channel and Instrument conventions ==
35
36 We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]]
37 )))
38
39 (% class="col-xs-12 col-sm-4" %)
40 (((
41 {{box title="**Contents**"}}
42 {{toc/}}
43 {{/box}}
44
45 (% class="box" %)
46 (((
47 = Trillium Compact 120 =
48
49 = [[image:Trillium compact120.jpg]] =
50
51 |**Frequency Band**|120 seconds to 100 Hz
52 |**Sensitivity**| 754 V/m/s
53 |**Size (Diameter x Height)**|9 x 13 cm
54 |**Weight**|1.1 kg
55 )))
56
57 (% class="box" %)
58 (((
59 = Trillium Compact PostHole 120 =
60
61 = [[image:Trillium compact posthole.jpg]] =
62
63 |**Frequency Band**|120 seconds to 100 Hz
64 |**Sensitivity**| 754 V/m/s
65 |**Size (Diameter x Height)**|10 x 17 cm
66 |**Weight**|3.1 kg
67 )))
68
69
70 (% class="box" %)
71 (((
72 = Lennartz LE-3D-Lite MkII =
73
74 = [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] =
75
76
77 |**Frequency Band**|1 seconds to 100 Hz
78 |**Sensitivity**| 400 V/m/s
79 |**Size (Diameter x Height)**|10 x 10 cm
80 |**Weight**|1.9 kg
81 )))
82
83 {{box title="= Guralp 40T =
84
85 [[image:Guralp 40T.jpg]]
86
87
88 |(% style=~"width:128px~" %)**Sensitivity**|(% style=~"width:103px~" %)
89 |(% style=~"width:128px~" %)**Size (Diameter x Height)**|(% style=~"width:103px~" %)17 x 23cm
90 |(% style=~"width:128px~" %)**Weight**|(% style=~"width:103px~" %)6.6 Kg"}}
91
92 {{/box}}
93
94 {{box title="= Guralp 3ESP =
95
96 [[image:GURALP 3ESP.jpg]]
97
98 |(% style=~"width:121px~" %)**Sensitivity**|(% style=~"width:110px~" %)
99 |(% style=~"width:121px~" %)**Size (Diameter x Height)**|(% style=~"width:110px~" %)17 x 27cm
100 |(% style=~"width:121px~" %)**Weight**|(% style=~"width:110px~" %)10.3Kg"}}
101
102 {{/box}}
103
104 {{box title="= Guralp 3ESPC =
105
106 [[image:Guralp 3ESPC.jpg]]
107
108 |(% style=~"width:122px~" %)**Sensitivity**|(% style=~"width:109px~" %)
109 |(% style=~"width:122px~" %)**Size (Diameter x Height)**|(% style=~"width:109px~" %)18 x 28cm
110 |(% style=~"width:122px~" %)**Weight**|(% style=~"width:109px~" %)8.2 Kg"}}
111
112 {{/box}}
113
114
115 )))