Changes for page Seismometers

Last modified by robert on 2025/06/15 15:01

From version 9.1
edited by robert
on 2024/01/10 18:42
Change comment: There is no comment for this version
To version 26.1
edited by robert
on 2024/01/11 10:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  (((
5 5  = Broadband sensors =
6 6  
7 -Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.Data Loggers.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
7 +Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.ANU LPR-200.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
8 8  
9 9  == Nanometrics ==
10 10  
... ... @@ -43,26 +43,35 @@
43 43  {{toc/}}
44 44  {{/box}}
45 45  
46 -{{box title="= Trillium Compact 120 =
47 -= **[[image:Trillium compact120.jpg||height=~"231~" width=~"219~"]]** =
48 -|(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)120 seconds
49 -|(% style=~"width:115px~" %)**Size (Diameter x Height)**|(% style=~"width:112px~" %)9 x 13 cm
50 -|(% style=~"width:115px~" %)**Weight**|(% style=~"width:112px~" %)1.1 kg
46 +(% class="box" %)
47 +(((
48 += Trillium Compact 120 =
51 51  
52 - "}}
53 -{{/box}}
50 += [[image:Trillium compact120.jpg]] =
54 54  
55 -{{box title="= Trillium Compact Posthole =
52 +|**Sensitivity**|120 seconds
53 +|**Size (Diameter x Height)**|9 x 13 cm
54 +|**Weight**|1.1 kg
55 +)))
56 +
57 +(% class="box" %)
58 +(((
59 += Trillium Compact PostHole 120 =
56 56  = [[image:Trillium compact posthole.jpg]] =
57 -|(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)120 seconds
58 -|(% style=~"width:139px~" %)**Size (Diameter x Height)**|(% style=~"width:88px~" %)10 x 17 cm
59 -|(% style=~"width:139px~" %)**Weight**|(% style=~"width:88px~" %)3.1 kg"}}
60 -{{/box}}
61 61  
62 -{{box title="= Lennartz LE-3D-Lite Mk2 =
63 -= [[image:LE3Dlite.jpg||alt="LE-3Dlite"]] =
64 -|(% style="~"width:115px~"" %)**Sensitivity **|(% style="~"width:112px~"" %)2 seconds
65 -|(% style="width:122px" %)**Size (Diameter x Height)**|(% style="width:105px" %)? cm
66 -|(% style="width:122px" %)**Weight (kg)**|(% style="width:105px" %)1.1
67 - "}}
68 -{{/box}}
62 +|**Sensitivity **|120 seconds
63 +|**Size (Diameter x Height)**|10 x 17 cm
64 +|**Weight**|3.1 kg"
65 +)))
66 +
67 +(% class="box" %)
68 +(((
69 += Lennartz LE-3D-Lite MkII =
70 += [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] =
71 +
72 +|**Sensitivity **|1 second
73 +|**Size (Diameter x Height)**|? x ? cm
74 +|**Weight**|? kg
75 +)))
76 +)))
77 +)))