Changes for page Seismometers
Last modified by robert on 2026/01/15 17:32
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. robert1 +XWiki.JackD - Content
-
... ... @@ -8,80 +8,56 @@ 8 8 9 9 == Nanometrics == 10 10 11 -Currently, 4 kinds of nanometric broadband seismic sensors are available. The Trillium Compact 120 s, Trillium Compact 20s, Trillium Compact Posthole, and most recently, the Trillium Compact Horizon. These seismometers are ideal for long-term deployments of multiple months. All of these seismometers are compatible with the LPR-200 and TSAWR loggers and are designed for low energy consumption.11 +Currently, 4 kinds of nanometric broadband seismic sensors are available. The Trillium Compact 120, Trillium Compact 20, Trillium Compact Posthole, and most recently, the Trillium Compact Horizon. These seismometers are ideal for long-term deployments of multiple months. All of these seismometers are compatible with the LPR-200 and TSAWR loggers and are designed for low energy consumption. 12 12 13 -=== Trillium Compact 120 s===13 +=== Trillium Compact 120 === 14 14 15 -The Trillium Compact 120 shassensitivitybandbetween 120 seconds and 100Hzbut is prone to corrosion when buried for long periods.They have a tilt tolerance of ~~10° but come with adjustable feet for leveling.15 +The Trillium Compact 120 has a recording range between 120 seconds and 100Hz. 16 16 17 - For more information, refer to the [[NanometricsTrillium Compact information sheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]17 +What info? 18 18 19 - ===TrilliumCompact20s ===19 +- Recording frequency range? 20 20 21 - TheTrillium Compact 20s looks identical to the Trillium Compact 120sand has a recording range between 20 seconds and 100 Hz. butis prone to corrosion when buried for long periods. They have a tilttolerance of ~~10° but come with adjustable feet for leveling.21 +- Sensitivity? 22 22 23 - Formoreinformation, refertothe [[NanometricsTrillium Compact informationsheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]23 +- Adjustable feet and levelling bubble? 24 24 25 - (%style="color:inherit;font-family:inherit;font-size:max(18px,min(20px, 14.4444px + 0.462963vw))"%)TrilliumCompactPosthole25 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]] 26 26 27 - TheTrillium CompactPosthole is designed with a robust casing allowing it to be deployed via direct-burial without a vault or protective case. It does NOT have leveling feet nor a bubble (**bring your own!**), nor can its mass be rebalanced. The cable is also quite a bit more stiff so may require burial at an increased depth. If installed inside a vault, the cable may also unbalance the sensor if left by itself. The instrument response is identical to a Trillium Compact 120.27 +=== Trillium Compact 20 === 28 28 29 - For more information, refer to the[[NanometricsTrilliumCompactPHinformationsheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca]]29 +The Trillium compact has a recording range between 20 seconds and 100Hz. These instruments also have a tilt tolerance of 10° making for efficient deployment. 30 30 31 - ===TrilliumCompactHorizon===31 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]] 32 32 33 - TheTrillium Compact Horizon is sort of a mix betweenthePostholeand Compact120, idealfor shallow direct bury deployments orinstances where packing weightandsizeis an importantconsideration.Its responseandsensitivityis identical to theTrillium Compact120s.33 +(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)Trillium Compact Posthole 34 34 35 - ===SmartSoloBroadbands===35 +The Trillium Compact Posthole is designed with a robust casing allowing it to be deployed without a vault or protective case. 36 36 37 - TwotypesofSmartSolo brandseismometersare currentlyavailable,oneof which isa broadbandseismometer.Moreinformationisavailable on the [[SmartSoloSeismometerspage>>doc:Instrumentation.SmartSolo Nodes.WebHome]].37 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca]] 38 38 39 +=== Trillium Compact Horizon === 40 + 41 +=== === 42 + 39 39 = Short period sensors = 40 40 41 41 Short-period (SP) sensors have limited sensitivity to longer periods, but are otherwise perfectly suitable for earthquake or other high-frequency analysis. They are generally defined as any instrument that begins to **lose sensitivity at periods larger than 10 seconds**. They tend to be smaller and more mechanically robust to broadband sensors. 42 42 43 -== =Lennartz Electronic LE-3D Lite (MkII) ===47 +== Lennartz Electronic LE-3D Lite (MkII) == 44 44 45 - TheLE-3D Lite are small, robust, short period sensors with a acorner period of 1 second.49 +etc 46 46 47 -== =SmartSoloBD3C-5===51 +== Sub-paragraph == 48 48 49 - Sometimes erroneously referred to as a "broadband node", the largercylinder-shaped BD3C-5 is technically a //short period //instrument as it has a corner period of 5 seconds (< 10). It is still a high gain seismometer however (e.g. channels ?H[NEZ]). More information is available on the [[SmartSolo Seismometers page>>doc:Instrumentation.SmartSolo Nodes.WebHome]].53 +etc 50 50 51 -== Geophone Sensors == 52 52 53 - "Geophones"are technically "very short period", with corner frequencies >= 5 Hz. ANSIR currentlyhave two geophone-typesensors availablefor loan:the3-Channel SmartSolo IGU-16HR and 1-Channel SmartSolo IGU-16, both with 5 Hz (0.2 second) corners.56 +== Channel and Instrument conventions == 54 54 55 -The center character in the channel codes should be "P", e.g. DPN, DPE, DHZ for 250 Hz. 56 - 57 -(% class="box warningmessage" %) 58 -((( 59 -Note that SmartSolo branded geophone channels have inverted polarity relative to traditional standards!!! This applies only to the IGU-16HR instruments and NOT the BD3C-5 instruments. 58 +We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] 60 60 ))) 61 61 62 -= Channel and Instrument conventions = 63 - 64 -We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] and also copied below: 65 - 66 -|=Band code|=Band type|=Sample rate (Hz)|=Corner period (sec) 67 -|F|…|≥ 1000 to < 5000|≥ 10 sec 68 -|G|…|≥ 1000 to < 5000|< 10 sec 69 -|D|…|≥ 250 to < 1000|< 10 sec 70 -|C|…|≥ 250 to < 1000|≥ 10 sec 71 -|E|Extremely Short Period|≥ 80 to < 250|< 10 sec 72 -|S|Short Period|≥ 10 to < 80|< 10 sec 73 -|H|High Broad Band|≥ 80 to < 250|≥ 10 sec 74 -|B|Broad Band|≥ 10 to < 80|≥ 10 sec 75 -|M|Mid Period|> 1 to < 10| 76 -|L|Long Period|≈ 1| 77 -|V|Very Long Period|≈ 0.1| 78 -|U|Ultra Long Period|≈ 0.01| 79 -|R|Extremely Long Period|≥ 0.0001 to < 0.001| 80 -|P|On the order of 0.1 to 1 day ^^1^^|≥ 0.00001 to < 0.0001| 81 -|T|On the order of 1 to 10 days ^^1^^|≥ 0.000001 to < 0.00001| 82 -|Q|Greater than 10 days ^^1^^|< 0.000001| 83 -))) 84 - 85 85 (% class="col-xs-12 col-sm-4" %) 86 86 ((( 87 87 {{box title="**Contents**"}} ... ... @@ -90,9 +90,9 @@ 90 90 91 91 (% class="box" %) 92 92 ((( 93 -= =Trillium Compact 120s==69 += Trillium Compact 120 = 94 94 95 -[[image:Trillium compact120.jpg]] 71 += [[image:Trillium compact120.jpg]] = 96 96 97 97 |**Frequency Band**|120 seconds to 100 Hz 98 98 |**Sensitivity**| 754 V/m/s ... ... @@ -102,9 +102,9 @@ 102 102 103 103 (% class="box" %) 104 104 ((( 105 -= =Trillium Compact PostHole 120s==81 += Trillium Compact PostHole 120 = 106 106 107 -[[image:Trillium compact posthole.jpg]] 83 += [[image:Trillium compact posthole.jpg]] = 108 108 109 109 |**Frequency Band**|120 seconds to 100 Hz 110 110 |**Sensitivity**| 754 V/m/s ... ... @@ -112,23 +112,12 @@ 112 112 |**Weight**|3.1 kg 113 113 ))) 114 114 115 -(% class="box" %) 116 -((( 117 -== Trillium Compact Horizon == 118 118 119 -[[image:20250305_100107.jpg]] 120 - 121 -|**Frequency Band**|120 seconds to 100 Hz 122 -|**Sensitivity**|754 V/m/s 123 -|**Size (Diameter x Height)**|8.6 x 13.8 cm 124 -|**Weight**|1.1 kg 125 -))) 126 - 127 127 (% class="box" %) 128 128 ((( 129 -= =Lennartz LE-3D-Lite MkII ==94 += Lennartz LE-3D-Lite MkII = 130 130 131 -[[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] 96 += [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] = 132 132 133 133 134 134 |**Frequency Band**|1 seconds to 100 Hz
- 20250305_100107.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.JackD - Size
-
... ... @@ -1,1 +1,0 @@ 1 -633.7 KB - Content