Changes for page Seismometers
Last modified by santi on 2025/07/23 15:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. santi1 +XWiki.robert - Content
-
... ... @@ -14,19 +14,19 @@ 14 14 15 15 The Trillium Compact 120 has sensitivity band between 120 seconds and 100 Hz but is prone to corrosion when buried for long periods. They have a tilt tolerance of ~~10° but come with adjustable feet for leveling. 16 16 17 - For more information, refer to the [[NanometricsTrilliumCompact information sheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]17 + For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]] 18 18 19 19 === Trillium Compact 20 === 20 20 21 -The Trillium Compact 20 looks identical to the TrilliumCompact120 andhas a recording range between 20 seconds and 100 Hz. but is prone to corrosion when buried for long periods. They have a tilt tolerance of ~~10° but come with adjustable feet for leveling.21 +The Trillium compact has a recording range between 20 seconds and 100 Hz. but is prone to corrosion when buried for long periods. They have a tilt tolerance of ~~10° but come with adjustable feet for leveling. 22 22 23 -For more information, refer to the [[NanometricsTrilliumCompact information sheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]23 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]] 24 24 25 25 (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)Trillium Compact Posthole 26 26 27 27 The Trillium Compact Posthole is designed with a robust casing allowing it to be deployed via direct-burial without a vault or protective case. It does NOT have leveling feet nor a bubble (**bring your own!**), nor can its mass be rebalanced. The cable is also quite a bit more stiff so may require burial at an increased depth. If installed inside a vault, the cable may also unbalance the sensor if left by itself. The instrument response is identical to a Trillium Compact 120. 28 28 29 -For more information, refer to the [[NanometricsTrilliumCompactPHinformation sheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca]]29 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca]] 30 30 31 31 === Trillium Compact Horizon === 32 32 ... ... @@ -51,27 +51,7 @@ 51 51 52 52 = Channel and Instrument conventions = 53 53 54 -We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] and also copied below: 55 - 56 -|=Band code|=Band type|=Sample rate (Hz)|=Corner period (sec) 57 -|F|…|≥ 1000 to < 5000|≥ 10 sec 58 -|G|…|≥ 1000 to < 5000|< 10 sec 59 -|D|…|≥ 250 to < 1000|< 10 sec 60 -|C|…|≥ 250 to < 1000|≥ 10 sec 61 -|E|Extremely Short Period|≥ 80 to < 250|< 10 sec 62 -|S|Short Period|≥ 10 to < 80|< 10 sec 63 -|H|High Broad Band|≥ 80 to < 250|≥ 10 sec 64 -|B|Broad Band|≥ 10 to < 80|≥ 10 sec 65 -|M|Mid Period|> 1 to < 10| 66 -|L|Long Period|≈ 1| 67 -|V|Very Long Period|≈ 0.1| 68 -|U|Ultra Long Period|≈ 0.01| 69 -|R|Extremely Long Period|≥ 0.0001 to < 0.001| 70 -|P|On the order of 0.1 to 1 day ^^1^^|≥ 0.00001 to < 0.0001| 71 -|T|On the order of 1 to 10 days ^^1^^|≥ 0.000001 to < 0.00001| 72 -|Q|Greater than 10 days ^^1^^|< 0.000001| 73 -|A|Administrative Instrument Channel|variable|NA 74 -|O|Opaque Instrument Channel|variable|NA 54 +We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] 75 75 ))) 76 76 77 77 (% class="col-xs-12 col-sm-4" %) ... ... @@ -82,7 +82,7 @@ 82 82 83 83 (% class="box" %) 84 84 ((( 85 - ==Trillium Compact 120==65 +Trillium Compact 120 86 86 87 87 [[image:Trillium compact120.jpg]] 88 88 ... ... @@ -94,7 +94,7 @@ 94 94 95 95 (% class="box" %) 96 96 ((( 97 - ==Trillium Compact PostHole 120==77 +Trillium Compact PostHole 120 98 98 99 99 [[image:Trillium compact posthole.jpg]] 100 100 ... ... @@ -106,7 +106,7 @@ 106 106 107 107 (% class="box" %) 108 108 ((( 109 - ==Trillium Compact Horizon==89 +Trillium Compact Horizon 110 110 111 111 [[image:20250305_100107.jpg]] 112 112 ... ... @@ -118,7 +118,7 @@ 118 118 119 119 (% class="box" %) 120 120 ((( 121 - ==Lennartz LE-3D-Lite MkII==101 +Lennartz LE-3D-Lite MkII 122 122 123 123 [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] 124 124