Changes for page Seismometers
Last modified by santi on 2025/07/23 15:43
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. robert1 +XWiki.santi - Content
-
... ... @@ -14,11 +14,11 @@ 14 14 15 15 The Trillium Compact 120 has sensitivity band between 120 seconds and 100 Hz but is prone to corrosion when buried for long periods. They have a tilt tolerance of ~~10° but come with adjustable feet for leveling. 16 16 17 - For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]17 + For more information, refer to the [[Nanometrics Trillium Compact information sheet>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]] 18 18 19 19 === Trillium Compact 20 === 20 20 21 -The Trillium compact has a recording range between 20 seconds and 100 Hz. but is prone to corrosion when buried for long periods. They have a tilt tolerance of ~~10° but come with adjustable feet for leveling. 21 +The Trillium Compact 20 looks identical to the Trillium Compact 120 and has a recording range between 20 seconds and 100 Hz. but is prone to corrosion when buried for long periods. They have a tilt tolerance of ~~10° but come with adjustable feet for leveling. 22 22 23 23 For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]] 24 24 ... ... @@ -51,7 +51,27 @@ 51 51 52 52 = Channel and Instrument conventions = 53 53 54 -We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] 54 +We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] and also copied below: 55 + 56 +|=Band code|=Band type|=Sample rate (Hz)|=Corner period (sec) 57 +|F|…|≥ 1000 to < 5000|≥ 10 sec 58 +|G|…|≥ 1000 to < 5000|< 10 sec 59 +|D|…|≥ 250 to < 1000|< 10 sec 60 +|C|…|≥ 250 to < 1000|≥ 10 sec 61 +|E|Extremely Short Period|≥ 80 to < 250|< 10 sec 62 +|S|Short Period|≥ 10 to < 80|< 10 sec 63 +|H|High Broad Band|≥ 80 to < 250|≥ 10 sec 64 +|B|Broad Band|≥ 10 to < 80|≥ 10 sec 65 +|M|Mid Period|> 1 to < 10| 66 +|L|Long Period|≈ 1| 67 +|V|Very Long Period|≈ 0.1| 68 +|U|Ultra Long Period|≈ 0.01| 69 +|R|Extremely Long Period|≥ 0.0001 to < 0.001| 70 +|P|On the order of 0.1 to 1 day ^^1^^|≥ 0.00001 to < 0.0001| 71 +|T|On the order of 1 to 10 days ^^1^^|≥ 0.000001 to < 0.00001| 72 +|Q|Greater than 10 days ^^1^^|< 0.000001| 73 +|A|Administrative Instrument Channel|variable|NA 74 +|O|Opaque Instrument Channel|variable|NA 55 55 ))) 56 56 57 57 (% class="col-xs-12 col-sm-4" %)