Changes for page Seismometers
Last modified by robert on 2025/06/15 15:01
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. robert1 +XWiki.JackD - Content
-
... ... @@ -4,7 +4,7 @@ 4 4 ((( 5 5 = Broadband sensors = 6 6 7 -Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation. ANULPR-200.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.7 +Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.Data Loggers.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors. 8 8 9 9 == Nanometrics == 10 10 ... ... @@ -43,37 +43,29 @@ 43 43 {{toc/}} 44 44 {{/box}} 45 45 46 - (% class="box"%)47 - (((48 - =TrilliumCompact46 +{{box title=" 47 += Trillium Compact 120 ="}} 48 +**[[image:Trillium compact120.jpg||height="231" width="219"]]** 49 49 50 -= [[image:Trillium compact120.jpg]] = 50 +(% style="width:189.859px" %) 51 +|(% style="width:136.377px" %)**Model** 52 +|(% style="width:136.377px" %)((( 53 +**Size (Diameter** 51 51 52 - |**Sensitivity**|120seconds53 -| **Size(Diameter x Height)**|9x 13cm54 -|**Weight**|1.1 kg55 - )))55 +**x Height cm)** 56 +)))|(% style="width:1px" %)9*13 57 +|(% style="width:136.377px" %)**Weight (kg)**|(% style="width:1px" %)1.1 58 +{{/box}} 56 56 57 - (%class="box"%)58 - (((59 - = Trillium Compact PostHole 120 =60 +{{box title="= Trillium Compact 20 ="}} 61 +[[image:Screenshot 2023-12-12 at 12-28-47 Trillium Compact Nanometrics.png||alt="TC120s"]] 62 +{{/box}} 60 60 61 -= [[image:Trillium compact posthole.jpg]] = 64 +{{box title="= Trillium Compact 120[[image:Trillium compact posthole.jpg]] ="}} 65 + 66 +{{/box}} 62 62 63 -|**Sensitivity **|120 seconds 64 -|**Size (Diameter x Height)**|10 x 17 cm 65 -|**Weight**|3.1 kg 68 +[[image:LE3Dlite.jpg||alt="LE-3Dlite"]] 69 +//Figure 2: LE-3Dlite MKII// 66 66 ))) 67 - 68 -(% class="box" %) 69 -((( 70 -= Lennartz LE-3D-Lite MkII = 71 - 72 -= [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] = 73 - 74 -|**Sensitivity **|1 second 75 -|**Size (Diameter x Height)**|? x ? cm 76 -|**Weight**|? kg 77 77 ))) 78 -))) 79 -)))
- Trillium compact 120.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.JackD - Size
-
... ... @@ -1,1 +1,0 @@ 1 -756.2 KB - Content