Changes for page Seismometers

Last modified by robert on 2025/06/15 15:01

From version 20.1
edited by robert
on 2024/01/10 21:18
Change comment: There is no comment for this version
To version 9.1
edited by robert
on 2024/01/10 18:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,7 @@
4 4  (((
5 5  = Broadband sensors =
6 6  
7 -Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.ANU LPR-200.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
7 +Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.Data Loggers.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
8 8  
9 9  == Nanometrics ==
10 10  
... ... @@ -43,35 +43,26 @@
43 43  {{toc/}}
44 44  {{/box}}
45 45  
46 -
47 47  {{box title="= Trillium Compact 120 =
48 -
49 -= [[image:Trillium compact120.jpg ]] =
50 -
47 += **[[image:Trillium compact120.jpg||height=~"231~" width=~"219~"]]** =
51 51  |(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)120 seconds
52 -|(% style=~"width:139px~" %)**Size (Diameter x Height)**|(% style=~"width:88px~" %)9 x 13 cm
53 -|(% style=~"width:139px~" %)**Weight**|(% style=~"width:88px~" %)1.1 kg"}}
54 -
49 +|(% style=~"width:115px~" %)**Size (Diameter x Height)**|(% style=~"width:112px~" %)9 x 13 cm
50 +|(% style=~"width:115px~" %)**Weight**|(% style=~"width:112px~" %)1.1 kg
51 +
52 + "}}
55 55  {{/box}}
56 56  
57 57  {{box title="= Trillium Compact Posthole =
58 -
59 59  = [[image:Trillium compact posthole.jpg]] =
60 -
61 61  |(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)120 seconds
62 62  |(% style=~"width:139px~" %)**Size (Diameter x Height)**|(% style=~"width:88px~" %)10 x 17 cm
63 63  |(% style=~"width:139px~" %)**Weight**|(% style=~"width:88px~" %)3.1 kg"}}
64 -
65 65  {{/box}}
66 66  
67 67  {{box title="= Lennartz LE-3D-Lite Mk2 =
68 -
69 -= [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment=~"center~"]] =
70 -
71 -|(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)2? seconds
72 -|(% style=~"width:139px~" %)**Size (Diameter x Height)**|(% style=~"width:88px~" %)? x ? cm
73 -|(% style=~"width:139px~" %)**Weight**|(% style=~"width:88px~" %)? kg"}}
74 -
63 += [[image:LE3Dlite.jpg||alt="LE-3Dlite"]] =
64 +|(% style="~"width:115px~"" %)**Sensitivity **|(% style="~"width:112px~"" %)2 seconds
65 +|(% style="width:122px" %)**Size (Diameter x Height)**|(% style="width:105px" %)? cm
66 +|(% style="width:122px" %)**Weight (kg)**|(% style="width:105px" %)1.1
67 + "}}
75 75  {{/box}}
76 -)))
77 -)))