5 5  = Broadband sensors =
6 6  
7 -Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.ANU LPR-200.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
7 +Broadband (or BB) sensors are especially sensitive to low frequency energy, and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However they are also well-suited for measuring high frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.Data Loggers.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short period sensors.
8 8  
9 9  == Nanometrics ==
10 10  
... ... @@ -39,21 +39,17 @@
39 39  
40 40  (% class="col-xs-12 col-sm-4" %)
41 41  (((
42 -
43 43  {{box title="**Contents**"}}
44 44  {{toc/}}
45 45  {{/box}}
46 46  
47 47  {{box title="= Trillium Compact 120 =
48 -
49 -= **[[image:Trillium compact120.jpg||data-xwiki-image-style-alignment=~"center~" height=~"231~" width=~"219~"]]** =
50 -
47 += **[[image:Trillium compact120.jpg||height=~"231~" width=~"219~"]]** =
51 51  |(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)120 seconds
52 52  |(% style=~"width:115px~" %)**Size (Diameter x Height)**|(% style=~"width:112px~" %)9 x 13 cm
53 53  |(% style=~"width:115px~" %)**Weight**|(% style=~"width:112px~" %)1.1 kg
54 54  
55 55   "}}
56 -
57 57  {{/box}}
58 58  
59 59  {{box title="= Trillium Compact Posthole =
... ... @@ -61,18 +61,12 @@
61 61  |(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)120 seconds
62 62  |(% style=~"width:139px~" %)**Size (Diameter x Height)**|(% style=~"width:88px~" %)10 x 17 cm
63 63  |(% style=~"width:139px~" %)**Weight**|(% style=~"width:88px~" %)3.1 kg"}}
64 - "}}
65 65  {{/box}}
66 66  
67 67  {{box title="= Lennartz LE-3D-Lite Mk2 =
68 -
69 -= [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment=~"center~"]] =
70 -
71 -|(% style=~"width:115px~" %)**Sensitivity **|(% style=~"width:112px~" %)2? seconds
72 -|(% style=~"width:139px~" %)**Size (Diameter x Height)**|(% style=~"width:88px~" %)? x ? cm
73 -|(% style=~"width:139px~" %)**Weight**|(% style=~"width:88px~" %)? kg"}}
63 += [[image:LE3Dlite.jpg||alt="LE-3Dlite"]] =
64 +|(% style="~"width:115px~"" %)**Sensitivity **|(% style="~"width:112px~"" %)2 seconds
65 +|(% style="width:122px" %)**Size (Diameter x Height)**|(% style="width:105px" %)? cm
66 +|(% style="width:122px" %)**Weight (kg)**|(% style="width:105px" %)1.1
74 74   "}}