Changes for page Field Deployment Guides

Last modified by KB on 2025/08/12 12:18

From version 6.1
edited by Sima Mousavi
on 2024/01/16 13:39
Change comment: There is no comment for this version
To version 3.1
edited by Sima Mousavi
on 2024/01/16 13:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,6 +10,8 @@
10 10  == **Site selection and preparation** ==
11 11  
12 12  * (((
13 +[[Size 1x1 m2>>image:20240116_125547.jpg||alt="Fire blanket, size 1m2"]]
14 +
13 13  Choose a location with minimal noise interference and away from urban areas, traffic, and industrial activities.
14 14  )))
15 15  * The site should be geologically stable and representative of the area's seismic characteristics.
... ... @@ -22,27 +22,14 @@
22 22  * Bury seismometers at an appropriate depth for noise reduction and stable ground coupling.
23 23  * Orient the sensors correctly using a compass, paying special attention to the north direction. When using a compass to orient the sensors, ensure it is kept away from metal objects or structures that could interfere with its magnetic field. Accurately determine the north direction for precise sensor orientation.
24 24  
25 -== **Setting up data**: ==
27 +== **Setting up data acquisition systems**: ==
26 26  
27 27  * Install data loggers or recorders compatible with the sensors.
28 28  * Ensure adequate storage capacity and configuration for the desired sampling rate and data format.
29 -* Establish a reliable power source, such as solar panels, batteries, or local grid connection. Use a compass to align solar panels facing north in the south hemisphere for optimal sunlight exposure.
30 -* Set up a GPS antenna to provide accurate time synchronization for the seismic data
31 -* Ensure the GPS antenna has a clear view of the sky for optimal signal reception.
32 -* Calibrate sensors and data acquisition systems for accuracy.
33 -* Test for sensitivity, noise levels, and overall performance.
34 34  
35 -== **Fire safety measures and documentation in seismic station installation** ==
36 36  
37 -* In bushfire-prone areas, clear a wide perimeter around the installation to reduce fire risk.
38 -* Use fireproof blankets to cover equipment, providing an additional layer of protection against fire damage.
39 -* Install a metal net over the entire setup to shield it from external elements
33 += Node Setup =
40 40  
41 -* Document the installation process, including sensor types, orientations, locations, and system configurations, along with fire safety measures implemented.
42 -* Record essential metadata for seismic data interpretation.
43 -
44 -= **Node Setup** =
45 -
46 46  Short term (~~30 day) battery powered nodes
47 47  
48 48  == Sub-paragraph ==
... ... @@ -67,8 +67,3 @@
67 67  //Figure 2: Flipping up the back of the fence onto the support picket to work comfortably//
68 68  )))
69 69  )))
70 -
71 -[[**Fireproof blanket**
72 -size: 1x1 m2>>image:20240116_125547.jpg||alt="Fire blanket" height="380" width="350"]]
73 -
74 -