19 19  
20 20  = **Installing Sensors** =
21 21  
22 -* Bury seismometers at an appropriate depth for noise reduction and stable ground coupling.
22 +* Bury seismometers at an appropriate depth for noise reduction and stable ground coupling, typically 0.7 - 1 metre depth.
23 23  * Orient the sensors correctly using a compass, paying special attention to the north direction. When using a compass to orient the sensors, ensure it is kept away from metal objects or structures that could interfere with its magnetic field. Accurately determine the north direction for precise sensor orientation.
24 24  
25 25  = **Setting up Data Logger** =
26 26  
27 27  * Install data loggers or recorders compatible with the sensors.
28 -* Ensure adequate storage capacity and configuration for the desired sampling rate and data format.
28 +* Ensure adequate storage capacity and configuration for the desired sampling rate and data format. Generally:
29 +
30 +64Gb card: 245 days @ 250hz or 610 days @ 100hz
31 +
32 +32Gb card: 122 days @ 250hz or 305 days @ 100hz
33 +
29 29  * Establish a reliable power source, such as solar panels, batteries, or local grid connection. Use a compass to align solar panels facing north in the south hemisphere for optimal sunlight exposure.