Changes for page Integrated Distributed Acoustic Sensing (iDAS)
Last modified by robert on 2024/05/17 16:52
From version 12.1
edited by Sima Mousavi
on 2024/01/29 16:37
on 2024/01/29 16:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -185,6 +185,83 @@ 185 185 * **Functionality:** Each mode presents the acoustic data from iDAS in unique formats. 186 186 * **Detailed Information:** See pages 19-23 of the Standard iDAS manual for comprehensive details on each mode. 187 187 188 + 189 + 190 +=== **Application Type Options** === 191 + 192 +1. **Diagnostic Setup Only:** 193 +1*. Retrieves current settings for a basic diagnostic overview. 194 +1. **Seismic Application:** 195 +1*. Sets Data Output Frequency to 1000 Hz. 196 +1*. Adjusts Data Output Spatial Resolution to 2 meters. 197 +1. **Flow Monitoring:** 198 +1*. Changes Data Output Frequency to 10,000 Hz. 199 +1*. Sets Data Output Spatial Resolution to 0.25 meters. 200 +1. **Security Monitoring:** 201 +1*. Configures Data Output Frequency to 1000 Hz. 202 +1*. Sets Data Output Spatial Resolution to 2 meters. 203 + 204 + 205 +[[image:1706508500303-165.png]] 206 + 207 + 208 +=== **Detailed Parameter Information** === 209 + 210 +1. **Time Decimation and Output Decimation:** 211 +1*. These values are calculated based on the physical fiber length. 212 +1. **Measure Length (m):** 213 +1*. Generated value: 10176 meters. 214 +1*. Note: 'Measure Length' includes the reference fiber inside the iDAS unit, differentiating it from 'Physical Fibre Length'. 215 +1. **Pulse Width (ns):** 216 +1*. Generated value: 50 nanoseconds. 217 +1*. Spatial Extent: A 50ns pulse corresponds to a 10m spatial extent. 218 + 219 + 220 +[[image:1706508761205-307.png]] 221 + 222 + 223 + 224 + 225 + 226 +=== **Optimal Light Management** === 227 + 228 +* **Objective:** Achieve balanced light distribution across the region of interest in the iDAS system. 229 + 230 +=== **Adjustment Guidelines** === 231 + 232 +1. **Setting Optical Power:** 233 +1*. Aim to have the start of the region of interest around or below +4000 units. 234 +1*. Ensure the far end of the region of interest does not enter a non-linear response scheme. 235 +1. **Consideration for Short Fibers:** 236 +1*. In cases where the fiber length is short and non-linear effects are not observed, set the Optical Power to its maximum. 237 +1*. **Power Scale:** The adjustment slider ranges from 0-100, representing the percentage of maximum power available. 238 + 239 +=== **Note on Optical Power Control** === 240 + 241 +* **Control Mechanism:** The slider provides a precise control mechanism to manage the intensity of light sent through the fiber. 242 +* **Monitoring and Adjustment:** Continuously monitor and adjust as necessary to ensure optimal performance. 243 + 244 + 245 + 246 + 247 + 248 + 249 + 250 + 251 + 252 + 253 + 254 + 255 + 256 + 257 + 258 + 259 + 260 + 261 + 262 + 263 + 264 + 188 188 === [[image:1706506304897-924.png]] === 189 189 190 190 [[image:1706506500585-231.png]] ... ... @@ -341,7 +341,6 @@ 341 341 342 342 343 343 344 - 345 345 [[Caption>>image:1706488806394-168.png]] 346 346 347 347
- 1706508500303-165.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.sima - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.7 MB - Content
- 1706508761205-307.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.sima - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content