... ... @@ -36,7 +36,7 @@
36 36  
37 37  If a logger stops receiving solar power, the station will drain and the battery may become unusable. Upon servicing a station in the field, the voltage of the 12v lead-acid battery should be assessed while not powering anything. If the voltage is below 10.5v, it is likely not suitable for use in the field and should be replaced with a functional battery. If the voltage is below 12.5v, it is a good idea to replace it with a fully charged 12v battery (though if this is not possible, it is ok to leave this battery so long as the station was alive on arrival.
38 38  
39 -If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours (~~2.5hrs).
39 +If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours.
40 40  
41 41  = GPS Considerations =
42 42  