Changes for page ANU Seismic Data Loggers

Last modified by Jack Dent on 2026/10/16 12:57

From version 76.1
edited by Jack Dent
on 2026/09/22 10:39
Change comment: There is no comment for this version
To version 79.1
edited by Jack Dent
on 2026/10/16 12:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -36,7 +36,7 @@
36 36  
37 37  If a logger stops receiving solar power, the station will drain and the battery may become unusable. Upon servicing a station in the field, the voltage of the 12v lead-acid battery should be assessed while not powering anything. If the voltage is below 10.5v, it is likely not suitable for use in the field and should be replaced with a functional battery. If the voltage is below 12.5v, it is a good idea to replace it with a fully charged 12v battery (though if this is not possible, it is ok to leave this battery so long as the station was alive on arrival.
38 38  
39 -If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours.
39 +If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours (~~2.5hrs).
40 40  
41 41  = GPS Considerations =
42 42  
... ... @@ -55,17 +55,17 @@
55 55  (% class="wikigeneratedid" id="HTheformatforANUSRSetup.txt2FLPR200swillbeasinglelineoftextthatlookslikethis:" %)
56 56  The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this:
57 57  
58 -{{{XXX195G0100010034864 2 }}}
58 +{{{XXX19M80100010034864 2 }}}
59 59  
60 60  //corresponding to//
61 61  
62 62   site **XXX19**,
63 - network **5G**,
63 + network **M8**,
64 64   sample rate **0100**, (i.e. 100 Hz)
65 65   "gps interval" **01** (once per hour~-~- don't change),
66 66   start mode (always **0**),
67 67   stop mode (always **0**),
68 - seismometer type (**3** = broadband (+/- 20V), 2 = Guralp (+/- 10V), 1 = shortperiod (+/- 5V),
68 + seismometer type (**3** = broadband (+/- 20V), 1 = Guralp (+/- 10V), 0 = shortperiod (+/- 5V),
69 69   and seismometer serial number (**4864**).
70 70  
71 71  (% class="box warningmessage" %)
... ... @@ -81,15 +81,15 @@
81 81  **NOTE: The format is shorter as they don't have an option to set the "GPS sync". The GPS sync number should be omitted otherwise the formatting will not work!**
82 82  )))
83 83  
84 -SITE15G02500039999 2
84 +SITE1M802500039999 2
85 85  
86 86  corresponding to site SITE1, 
87 87  
88 - network 5G
88 + network M8
89 89   sample rate 0250, (i.e. 250 Hz)
90 90   start mode (always 0),
91 91   stop mode (always 0),
92 - seismometer type (3 = broadband (+/- 20V), 2 = Guralp (+/- 10V), 1 = shortperiod (+/- 5V),
92 + seismometer type (3 = broadband (+/- 20V), 1 = Guralp (+/- 10V), 0 = shortperiod (+/- 5V),
93 93   and seismometer serial number (9999).
94 94  
95 95  
... ... @@ -311,6 +311,9 @@
311 311  
312 312  
313 313  
314 +
315 +
316 +
314 314  (% class="box" %)
315 315  (((
316 316  = TerraSAWR Specs =
... ... @@ -380,5 +380,8 @@
380 380  
381 381  
382 382  
386 +
387 +
388 +
383 383  
384 384  )))