Changes for page ANU Seismic Data Loggers

Last modified by Jack Dent on 2026/10/16 12:57

From version 76.1
edited by Jack Dent
on 2026/09/22 10:39
Change comment: There is no comment for this version
To version 77.1
edited by Jack Dent
on 2026/09/22 13:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -36,7 +36,7 @@
36 36  
37 37  If a logger stops receiving solar power, the station will drain and the battery may become unusable. Upon servicing a station in the field, the voltage of the 12v lead-acid battery should be assessed while not powering anything. If the voltage is below 10.5v, it is likely not suitable for use in the field and should be replaced with a functional battery. If the voltage is below 12.5v, it is a good idea to replace it with a fully charged 12v battery (though if this is not possible, it is ok to leave this battery so long as the station was alive on arrival.
38 38  
39 -If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours.
39 +If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours (~~2.5hrs).
40 40  
41 41  = GPS Considerations =
42 42  
... ... @@ -311,6 +311,7 @@
311 311  
312 312  
313 313  
314 +
314 314  (% class="box" %)
315 315  (((
316 316  = TerraSAWR Specs =
... ... @@ -380,5 +380,6 @@
380 380  
381 381  
382 382  
384 +
383 383  
384 384  )))