... ... @@ -32,6 +32,12 @@
32 32  (% class="wikigeneratedid" %)
33 33  In the case of an LPR, there is a large compartment for housing an internal battery, able to accommodate anything from a 10-30Ah battery. To use a standard lead acid battery with a positive and negative terminal, a 6 pin adaptor must be used. This ensures the voltage from the external power port (pins A and C) connect to the battery and ensure the system actually recharges. (See [[Peripheral Equipment>>doc:Instrumentation.Peripheral Equipment.WebHome]] for a more comprehensive overview of this kind of setup)
34 34  
35 +=== Recharging a logger battery ===
36 +
37 +If a logger stops receiving solar power, the station will drain and the battery may become unusable. Upon servicing a station in the field, the voltage of the 12v lead-acid battery should be assessed while not powering anything. If the voltage is below 10.5v, it is likely not suitable for use in the field and should be replaced with a functional battery. If the voltage is below 12.5v, it is a good idea to replace it with a fully charged 12v battery (though if this is not possible, it is ok to leave this battery so long as the station was alive on arrival.
38 +
39 +If a 12v lead-acid battery is collected from the field and is still above 10.5v, recharge it fully using a 12v battery charger. These are easily acquired at auto or electronics store. Recharging a 12v lead-acid battery with a capacity of about 10Ah should take a couple of hours (~~2.5hrs).
40 +
35 35  = GPS Considerations =
36 36  
37 37  GPS is required for the data to have accurate timestamps. A standard 3-5V 1575.42 Mhz coaxial "dongle" antenna works fine and can be found for relatively cheap (e.g. [[https:~~/~~/www.elecbee.com/en-3555-gps-antenna-bnc-male-for-garmin-gps-120120xl125-sounder-with-cable-2m) >>https://www.elecbee.com/en-3555-gps-antenna-bnc-male-for-garmin-gps-120120xl125-sounder-with-cable-2m]]. Anything that locates satellites and gives you a GPS-synced time works!
... ... @@ -49,12 +49,12 @@
49 49  (% class="wikigeneratedid" id="HTheformatforANUSRSetup.txt2FLPR200swillbeasinglelineoftextthatlookslikethis:" %)
50 50  The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this:
51 51  
52 -{{{XXX195G0100010034864 2 }}}
58 +{{{XXX19M80100010034864 2 }}}
53 53  
54 54  //corresponding to//
55 55  
56 56   site **XXX19**,
57 - network **5G**,
63 + network **M8**,
58 58   sample rate **0100**, (i.e. 100 Hz)
59 59   "gps interval" **01** (once per hour~-~- don't change),
60 60   start mode (always **0**),
... ... @@ -75,11 +75,11 @@
75 75  **NOTE: The format is shorter as they don't have an option to set the "GPS sync". The GPS sync number should be omitted otherwise the formatting will not work!**
76 76  )))
77 77  
78 -SITE15G02500039999 2
84 +SITE1M802500039999 2
79 79  
80 80  corresponding to site SITE1, 
81 81  
82 - network 5G
88 + network M8
83 83   sample rate 0250, (i.e. 250 Hz)
84 84   start mode (always 0),
85 85   stop mode (always 0),
... ... @@ -304,6 +304,9 @@
304 304  
305 305  
306 306  
313 +
314 +
315 +
307 307  (% class="box" %)
308 308  (((
309 309  = TerraSAWR Specs =
... ... @@ -372,5 +372,8 @@
372 372  
373 373  
374 374  
384 +
385 +
386 +
375 375  
376 376  )))