Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/08/08 16:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -104,8 +104,8 @@ 104 104 105 105 This menu also displays the firmware version, battery, external, and solar voltages, and the temperature of the system. 106 106 107 -* Check that all//Initialisation Parameters//are marked as successful.108 -* Check that solar voltage is above 10 V i nthe software,orpreferrably physicallycheckthatthe battery'svoltageis increasingvia a DMM.107 +* Check all Initialisation Parameters are marked as successful. 108 +* Check that solar voltage is above 10 V, otherwise the station will not last long. 109 109 110 110 == Live Seismometer Data == 111 111 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 This menu displays the status of the stations' GPS connection. The screen lists; UTC time, UTC date, latitude, longitude, altitude, number of satellite connections, and SNR. 121 121 122 -* Check that the station is connected to satellites . 3 or more should be perfectly adequate to keep time.122 +* Check that the station is connected to satellites 123 123 124 124 == SD Information == 125 125 ... ... @@ -152,7 +152,7 @@ 152 152 153 153 (% class="box errormessage" %) 154 154 ((( 155 - Again,ensure the 'RECORD ON RESTART' option is marked with a cross(the default setting).This ensures that the logger will record any time it receives enough power!155 +NOTE: Ensure the 'RECORD ON RESTART' option is marked with a cross. 156 156 ))) 157 157 158 158 (% class="wikigeneratedid" %) ... ... @@ -168,58 +168,30 @@ 168 168 169 169 = Instrument Response = 170 170 171 -Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via a 5th order SINC filter, then another four FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter (for better or worse!).171 +Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via a 5th order SINC filter, then another four FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter. 172 172 173 -In the logger's menu, the user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. This gain manifests itself in stage 2 in the response information. 173 +{{info}} 174 +The Stage 3 SINC coefficients (600+) during the initial 1024k > 16k decimation were left off as they slowed down the process x10 and contribute very little (< 0.3 db, < 0.31 ms) to the end result 175 +{{/info}} 174 174 175 - //(The600+Stage3SINCcoefficientsduringtheinitial 1024k>16kdecimationwereleftoffastheysloweddowntheprocessx10 and contributeatmost0.3db amplitude and 0.31msphasedelaydiscrepancies,andprimarilyonlytofrequenciesnear the nyquist.Ifforsomereason youwanttoaddthisphasemanuallywecan share theparameterswith you.)//177 +The user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. This gain manifests itself in stage 2 in the response information. 176 176 177 - Youightnoticethat theresponseinformationmaycomeintwoversions.Theresponse fromour website (seelinkbelow) includesthe2nd "sensorgain"stageforclarity.e.g.here isTrillium Compact 120 & ANU Loggerresponse179 +Instrument response can be downloaded from IRIS [[Nominal Response Library>>https://ds.iris.edu/ds/nrl/]] if need be, or [[directly from us>>http://auspass.edu.au/data/logger_response]] , or by downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ). 178 178 179 -##Channel Response 180 - From M/S (Velocity) to COUNTS () 181 - Overall Sensitivity: 3.95452e+08 defined at 1.000 Hz 182 - 8 stages: 183 - Stage 1: PolesZerosResponseStage from M/S to V, gain: 754.3 184 - Stage 2: ResponseStage from V to V, gain: 0.25 185 - Stage 3: CoefficientsTypeResponseStage from V to COUNTS, gain: 2.09715e+06 186 - Stage 4: FIRResponseStage from COUNTS to COUNTS, gain: 1 187 - Stage 5: FIRResponseStage from COUNTS to COUNTS, gain: 1 188 - Stage 6: FIRResponseStage from COUNTS to COUNTS, gain: 0.99998 189 - Stage 7: FIRResponseStage from COUNTS to COUNTS, gain: 1 190 - Stage 8: FIRResponseStage from COUNTS to COUNTS, gain: 1## 191 191 182 +[[Amplitude and phase response for ANU logger at 50 Hz>>image:ANU_50hz_response.png]] 192 192 193 - However,if retrievingfrom AusPassorIRIS, the2nd "sensor gain"stageis combinedwiththeloggergain. This has no affect,butwill be one stageshort:184 +[[Amplitude and phase response for ANU logger at 100 Hz>>image:ANU_100hz_response.png]] 194 194 195 -##Channel Response 196 - From M/S (Velocity) to COUNTS () 197 - Overall Sensitivity: 3.9546e+08 defined at 1.000 Hz 198 - 6 stages: 199 - Stage 1: PolesZerosResponseStage from M/S to V, gain: 754.3 200 - Stage 2: CoefficientsTypeResponseStage from V to COUNTS, gain: 524288 201 - Stage 3: FIRResponseStage from COUNTS to COUNTS, gain: 1 202 - Stage 4: FIRResponseStage from COUNTS to COUNTS, gain: 1 203 - Stage 5: FIRResponseStage from COUNTS to COUNTS, gain: 0.99998 204 - Stage 6: FIRResponseStage from COUNTS to COUNTS, gain: 1## 205 205 187 +[[Amplitude and phase response for ANU logger at 250 Hz>>image:ANU_250hz_response.png]] 206 206 207 -For the most part, the data logger response essentially flat when the samplerate output is set to 100 Hz or less and for seismological purposes is likely to be impossible to detect below 20 Hz regardless. 208 208 209 - Instrument response can be downloaded from IRIS[[Nominal Response Library>>https://ds.iris.edu/ds/nrl/]]ifneedbe, or [[directly from us>>http://auspass.edu.au/data/logger_response]],orbydownloadingtheesponseofan equivalentsensorat AusPass (e.g. get_stations(level='response') ).190 +[[Amplitude and phase response for ANU logger at 1000 Hz>>image:ANU_1000hz_response.png]] 210 210 211 211 212 -[[ Amplitude andphaseresponseforANUlogger at50Hz>>image:ANU_50hz_response.png||data-xwiki-image-style-alignment="center"height="356" width="475"]]193 +[[Huddle test comparing a Trillium Compact 120 + TerraSAWR vs a Trillium Compact 120 + Nanometrics Centaur (M8.AUANU)>>image:TC120_ANU_vs_CENTAUR.png||data-xwiki-image-style-alignment="center"]] 213 213 214 -[[Amplitude and phase response for ANU logger at 100 Hz>>image:ANU_100hz_response.png||data-xwiki-image-style-alignment="center" height="355" width="473"]] 215 - 216 -[[Amplitude and phase response for ANU logger at 250 Hz>>image:ANU_250hz_response.png||data-xwiki-image-style-alignment="center" height="359" width="479"]] 217 - 218 -[[Amplitude and phase response for ANU logger at 1000 Hz>>image:ANU_1000hz_response.png||data-xwiki-image-style-alignment="center" height="367" width="489"]] 219 - 220 - 221 -[[Huddle test comparing a Trillium Compact 120 + TerraSAWR vs a Trillium Compact 120 + Nanometrics Centaur (M8.AUANU) at 100 Hz>>image:TC120_ANU_vs_CENTAUR.png||data-xwiki-image-style-alignment="center"]] 222 - 223 223 = ANU TerraSAWR (Gen 3, FW 3.5a, 2014- current) = 224 224 225 225 Earliest known model is dated July 2014 (though first deployed in 2019) and our current flagship model. Lightweight and small. ... ... @@ -261,11 +261,6 @@ 261 261 262 262 263 263 264 - 265 - 266 - 267 - 268 - 269 269 (% class="box" %) 270 270 ((( 271 271 = TerraSAWR Specs = ... ... @@ -316,9 +316,4 @@ 316 316 [[image:LPR battery.jpg]] 317 317 ))) 318 318 ))) 319 - 320 - 321 - 322 - 323 - 324 324 )))
- ANU_1000hz_response.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -2 3.5KB1 +22.7 KB - Content
- ANU_100hz_response.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -21. 4KB1 +21.3 KB - Content
- ANU_250hz_response.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -2 3.7KB1 +22.9 KB - Content
- ANU_50hz_response.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -21 7931 +21828 - Content