Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/08/08 16:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -104,8 +104,8 @@ 104 104 105 105 This menu also displays the firmware version, battery, external, and solar voltages, and the temperature of the system. 106 106 107 -* Check that all//Initialisation Parameters//are marked as successful.108 -* Check that solar voltage is above 10 V i nthe software,orpreferrably physicallycheckthatthe battery'svoltageis increasingvia a DMM.107 +* Check all Initialisation Parameters are marked as successful. 108 +* Check that solar voltage is above 10 V, otherwise the station will not last long. 109 109 110 110 == Live Seismometer Data == 111 111 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 This menu displays the status of the stations' GPS connection. The screen lists; UTC time, UTC date, latitude, longitude, altitude, number of satellite connections, and SNR. 121 121 122 -* Check that the station is connected to satellites . 3 or more should be perfectly adequate to keep time.122 +* Check that the station is connected to satellites 123 123 124 124 == SD Information == 125 125 ... ... @@ -152,7 +152,7 @@ 152 152 153 153 (% class="box errormessage" %) 154 154 ((( 155 - Again,ensure the 'RECORD ON RESTART' option is marked with a cross(the default setting).This ensures that the logger will record any time it receives enough power!155 +NOTE: Ensure the 'RECORD ON RESTART' option is marked with a cross. 156 156 ))) 157 157 158 158 (% class="wikigeneratedid" %) ... ... @@ -168,10 +168,10 @@ 168 168 169 169 = Instrument Response = 170 170 171 -Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via a 5th order SINC filter, then another four FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter. For the most part, the data logger response essentially flat when the samplerate output is set to 100 Hz or less and for seismological purposes is likely to be impossible to detect below 20 Hz regardless.171 +Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via a 5th order SINC filter, then another four FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter. 172 172 173 173 {{info}} 174 -The 600+Stage 3 SINC coefficients during the initial 1024k > 16k decimation were left off as they slowed down the process x10 and contributeatmost 0.3 dbamplitudeand0.31 msphase delay discrepancies, and primarily onlytofrequencies nearthenyquist. If for somereasonyou want to addthis phase manually we can sharethe parameterswith you.174 +The Stage 3 SINC coefficients (600+) during the initial 1024k > 16k decimation were left off as they slowed down the process x10 and contribute very little (< 0.3 db, < 0.31 ms) to the end result 175 175 {{/info}} 176 176 177 177 The user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. This gain manifests itself in stage 2 in the response information. ... ... @@ -233,7 +233,6 @@ 233 233 234 234 235 235 236 - 237 237 (% class="box" %) 238 238 ((( 239 239 = TerraSAWR Specs =