Changes for page ANU Seismic Data Loggers

Last modified by robert on 2025/08/08 16:09

From version 55.1
edited by robert
on 2025/08/06 15:07
Change comment: There is no comment for this version
To version 54.1
edited by santi
on 2025/07/22 18:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.robert
1 +XWiki.santi
Content
... ... @@ -180,14 +180,17 @@
180 180  
181 181  [[Huddle test comparing a Trillium Compact 120 + TerraSAWR vs a Trillium Compact 120 + Nanometrics Centaur (M8.AUANU)>>image:TC120_ANU_vs_CENTAUR.png||data-xwiki-image-style-alignment="center"]]
182 182  
183 -= ANU TerraSAWR (Gen 3, FW 3.5a, 2014- current) =
183 += ANU TerraSAWR (Gen 3, FW 3.5a, 2017- current) =
184 184  
185 -Earliest known model is dated July 2014 (though first deployed in 2019) and our current flagship model. Lightweight and small.
185 +Not sure there's much left to say
186 186  
187 -= ANU LPR-200 (Gen 2, FW 2.6a/2.7a, 2011 - current) =
188 188  
189 -Earliest known model is dated May 2011 (but first deployed November 2012) and still in use today. Potentially capable of housing much larger batteries than the TSAWR due to the larger cavity space.
190 190  
189 += ANU LPR-200 (Gen 2, FW 2.6a/2.7a, 2013 - current) =
190 +
191 +Ditto the mighty LPR!
192 +
193 +
191 191  = ANU "ANUSR" (Gen 1, 2003? - 2012) =
192 192  
193 193  This logger has been retired for a long time and has a different instrument response. It used modular component boards and was powered via an acrylic case of 6 x 6V lantern batteries. There is a somewhat complete one above the CAT lab door if anyone is so inclined to have a look.
... ... @@ -218,7 +218,6 @@
218 218  
219 219  
220 220  
221 -
222 222  (% class="box" %)
223 223  (((
224 224  = TerraSAWR Specs =