Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/08/08 16:09
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. santi1 +XWiki.JackD - Content
-
... ... @@ -14,9 +14,9 @@ 14 14 15 15 Both the LPR-200 (or "Low Power Recorder" 200) and TerraSAWR are designed to use as little power as possible, and more or less use the same amount of power. 16 16 17 -At 100 Hz and with a GPS cable connected these loggers draw about 220 mW of power once the screen is off (higher sample rates draw more power but only marginally, < 5 17 +At 100 Hz and with a GPS cable connected these loggers draw about 220 mW of power once the screen is off (higher sample rates draw more power but only marginally, < 5mW). Adding a sensor (e.g. a Trillium Compact 120) increases this to approximately 400 mW, or 0.4 volt-amps. So, in theory 7 Ah battery should last about 10 days without a solar panel, but in practice it seems to be a bit closer to 8 which may be due to variability in power drain while in getting GPS locks. 18 18 19 -For very sunny environments (latitudes < 30) a 20 olts10 Watt solar panel should have no issue keeping these loggers alive over the summer months, and assuming unobstructed skies should also be fine over winter. However there is no harm in using 20 or even a 40 Watt panel, especially for high latitudes, coastal regions, or areas without a full sky view. In theory up to a 60 Watt solar panel is fine, but we don't recommend anything over 40 Watts and that amount of power is already overkill.19 +For very sunny environments (latitudes < 30) a 20V 10 Watt solar panel should have no issue keeping these loggers alive over the summer months, and assuming unobstructed skies should also be fine over winter. However there is no harm in using 20 or even a 40 Watt panel, especially for high latitudes, coastal regions, or areas without a full sky view. In theory up to a 60 Watt solar panel is fine, but we don't recommend anything over 40 Watts and that amount of power is already overkill. 20 20 21 21 (% class="box infomessage" %) 22 22 ((( ... ... @@ -24,7 +24,7 @@ 24 24 ))) 25 25 26 26 (% class="wikigeneratedid" %) 27 -In the case of an LPR, there is a large compartment for housing an internal battery, able to accommodate anything from a 10-30Ah battery. To use a standard lead acid battery with a positive and negative terminal, a 6 pin adaptor must be used. This ensures the voltage from the external power port (pins A and C) connect to the battery and ensure the system actually recharges. (See [[Peripheral Equipment>>doc:Instrumentation.PeripheralEquipment.WebHome]]for a more comprehensive overview of this kind of setup)27 +In the case of an LPR, there is a large compartment for housing an internal battery, able to accommodate anything from a 10-30Ah battery. To use a standard lead acid battery with a positive and negative terminal, a 6 pin adaptor must be used. This ensures the voltage from the external power port (pins A and C) connect to the battery and ensure the system actually recharges. (See Peripheral Equipment for a more comprehensive overview of this kind of setup) 28 28 29 29 = Data Card Formatting and Information = 30 30 ... ... @@ -89,7 +89,7 @@ 89 89 90 90 * XX.ANUSR network and station name 91 91 * 100 Hz Sample Rate 92 -* 40 92 +* 40V pp (or +/- 20 V) gain / Trillium Compact seismometer version 93 93 * Record on Restart enabled 94 94 95 95 Note that if a user sets the gain incorrectly, this can be fixed later (assuming nothing clipped) by multiplying or dividing by factors of 2. The gain setting can be looked up from the logfile, else you may have to guess from a PSD or other method. ... ... @@ -137,7 +137,7 @@ 137 137 138 138 The seismometer model and serial number (up to 10 characters) can be set. Seismometer model options include: 139 139 140 -* Trillium Compact (same for 20 sand 120s models)140 +* Trillium Compact (same for 20 and 120) 141 141 * CMG - 3ESP 142 142 * Guralp 40T 143 143 * LE-3D Lite ... ... @@ -220,7 +220,6 @@ 220 220 221 221 222 222 223 - 224 224 (% class="box" %) 225 225 ((( 226 226 = TerraSAWR Specs =