Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/06/30 19:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -165,10 +165,10 @@ 165 165 166 166 = Instrument Response = 167 167 168 -Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via a 5th order SINC filter, then another four FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter.168 +Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via various stages. First via a 5th order SINC filter, then another 32x via 3-4 2x or 4x FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter. 169 169 170 170 {{info}} 171 - TheStage 3 SINCcoefficients(600+) duringthe initial1024k > 16k decimationwereleftoffastheysloweddowntheprocessx10andcontributeverylittle(< 0.3db,<0.31 ms)to the endresult171 +All SINC and FIR filters are performed internally within the logger and all phase delays are accounted for. Thus, the FIR coefficients and delays are not needed/given in the response information. 172 172 {{/info}} 173 173 174 174 The user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. This gain manifests itself in stage 2 in the response information. ... ... @@ -175,7 +175,6 @@ 175 175 176 176 Instrument response can be downloaded from IRISĀ [[Nominal Response Library>>https://ds.iris.edu/ds/nrl/]] if need be, orĀ [[directly from us>>http://auspass.edu.au/data/logger_response]] , or by downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ). 177 177 178 -[[Huddle test comparing a Trillium Compact 120 + TerraSAWR vs a Trillium Compact 120 + Nanometrics Centaur (M8.AUANU)>>image:TC120_ANU_vs_CENTAUR.png||data-xwiki-image-style-alignment="center"]] 179 179 180 180 = ANU TerraSAWR (Gen 3, FW 3.5a, 2017- current) = 181 181 ... ... @@ -213,8 +213,6 @@ 213 213 214 214 215 215 216 - 217 - 218 218 (% class="box" %) 219 219 ((( 220 220 = TerraSAWR Specs =
- TC120_ANU_vs_CENTAUR.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.robert - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.0 KB - Content