Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/08/08 16:09
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. robert1 +XWiki.JackD - Content
-
... ... @@ -23,6 +23,9 @@ 23 23 Power issues are easy and cheap to solve relative to the cost of your experiment, don't skimp! 24 24 ))) 25 25 26 +(% class="wikigeneratedid" %) 27 +In the case of an LPR, there is a large compartment for housing an internal battery, able to accommodate anything from a 10-30Ah battery. To use a standard lead acid battery with a positive and negative terminal, a 6 pin adaptor must be used. This ensures the voltage from the external power port (pins 28 + 26 26 = Data Card Formatting and Information = 27 27 28 28 Both the TerraSAWR and LPR-200 require SD Cards to be formatted in FAT32 filesystem. For 64Gb cards it can be difficult to format in FAT32, but [[software >>http://auspass.edu.au/field/fat32cardformatter.exe]]is available. ANU recommend SanDisk Extreme 150 mb/s cards in either 32 or 64Gb size. We strongly discourage using cards larger than 64Gb, and in general smaller cards are less likely to fail. We have also found that "adapter" cards (e.g. SD to microSD) are prone to having write issues and **strongly** advise against them. ... ... @@ -165,10 +165,10 @@ 165 165 166 166 = Instrument Response = 167 167 168 -Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via variousstages. First via a5th order SINC filter, then another32x via 3-4 2xor4xFIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter.171 +Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog to digital) chip in both loggers originally samples at 1024000 Hz and downsamples towards the output data rate via a 5th order SINC filter, then another four FIR filters. If the output is below 250 Hz, a final "pure" /5 decimation is done without any sort of FIR filter. 169 169 170 170 {{info}} 171 - AllSINCand FIRfiltersareperformedrnallywithinthe loggerandallphasedelaysare accountedfor.Thus,theFIR coefficients anddelaysarenotneeded/givenintheresponseinformation.174 +The Stage 3 SINC coefficients (600+) during the initial 1024k > 16k decimation were left off as they slowed down the process x10 and contribute very little (< 0.3 db, < 0.31 ms) to the end result 172 172 {{/info}} 173 173 174 174 The user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. This gain manifests itself in stage 2 in the response information. ... ... @@ -175,6 +175,7 @@ 175 175 176 176 Instrument response can be downloaded from IRISĀ [[Nominal Response Library>>https://ds.iris.edu/ds/nrl/]] if need be, orĀ [[directly from us>>http://auspass.edu.au/data/logger_response]] , or by downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ). 177 177 181 +[[Huddle test comparing a Trillium Compact 120 + TerraSAWR vs a Trillium Compact 120 + Nanometrics Centaur (M8.AUANU)>>image:TC120_ANU_vs_CENTAUR.png||data-xwiki-image-style-alignment="center"]] 178 178 179 179 = ANU TerraSAWR (Gen 3, FW 3.5a, 2017- current) = 180 180 ... ... @@ -212,6 +212,9 @@ 212 212 213 213 214 214 219 + 220 + 221 + 215 215 (% class="box" %) 216 216 ((( 217 217 = TerraSAWR Specs =
- TC120_ANU_vs_CENTAUR.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +63.9 KB - Content