... ... @@ -10,19 +10,6 @@ 10 10 ))) 11 11 ))) 12 12 13 -= Power Considerations = 14 - 15 -Both the LPR-200 (or "Low Power Recorder" 200) and TerraSAWR are designed to use as little power as possible, and more or less use the same amount of power. 16 - 17 -At 100 Hz and with a GPS cable connected these loggers draw about 220 mW of power once the screen is off (higher sample rates draw more power but only marginally, < 5mW). Adding a sensor (e.g. a Trillium Compact 120) increases this to approximately 400 mW, or 0.4 volt-amps. So, in theory 7 Ah battery should last about 10 days without a solar panel, but in practice it seems to be a bit closer to 8 which may be due to variability in power drain while in getting GPS locks. 18 - 19 -For very sunny environments (latitudes < 30) a 20V 10 Watt solar panel should have no issue keeping these loggers alive over the summer months, and assuming unobstructed skies should also be fine over winter. However there is no harm in using 20 or even a 40 Watt panel, especially for high latitudes, coastal regions, or areas without a full sky view. In theory up to a 60 Watt solar panel is fine, but we don't recommend anything over 40 Watts and that amount of power is already overkill. 20 - 21 -(% class="box infomessage" %) 22 -((( 23 -Power issues are easy and cheap to solve relative to the cost of your experiment, don't skimp! 24 -))) 25 - 26 26 = Data Card Formatting and Information = 27 27 28 28 Both the TerraSAWR and LPR-200 require SD Cards to be formatted in FAT32 filesystem. For 64Gb cards it can be difficult to format in FAT32, but [[software >>http://auspass.edu.au/field/fat32cardformatter.exe]]is available. ANU recommend SanDisk Extreme 150 mb/s cards in either 32 or 64Gb size. We strongly discourage using cards larger than 64Gb, and in general smaller cards are less likely to fail. We have also found that "adapter" cards (e.g. SD to microSD) are prone to having write issues and **strongly** advise against them. ... ... @@ -29,27 +29,25 @@ 29 29 30 30 The loggers can be "pre-programmed" with information (e.g. site name, sampling rate, etc) or they can be programmed in the field using the buttons on the logger. To pre-program the cards you simply edit a text file (named "[[ANUSRSetup.txt>>http://auspass.edu.au/field/ANUSRSetup.txt]]" for the LPRs, or "[[tSAWRSetup.txt>>http://auspass.edu.au/field/tSAWRSetup.txt]]" for the TerraSAWRs) and place it in the root directory on the SDCard. When the logger boots up, it will parse and load this information. 31 31 32 -== The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this: == 19 +=== The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this: === 33 33 34 34 {{{XXX195G0100010034864 2 }}} 35 35 36 -//corresponding to// 23 +corresponding to site XXX19, 24 + network 5G, 25 + sample rate 0100, (i.e. 100 Hz) 26 + "gps interval" 01 (once per hour~-~- don't change), 27 + start mode (always 0), 28 + stop mode (always 0), 29 + seismometer type (3 = broadband (+/- 20V), 2 = Guralp (+/- 10V), 1 = shortperiod (+/- 5V), 30 + and seismometer serial number (4864). 37 37 38 - site **XXX19**, 39 - network **5G**, 40 - sample rate **0100**, (i.e. 100 Hz) 41 - "gps interval" **01** (once per hour~-~- don't change), 42 - start mode (always **0**), 43 - stop mode (always **0**), 44 - seismometer type (**3** = broadband (+/- 20V), 2 = Guralp (+/- 10V), 1 = shortperiod (+/- 5V), 45 - and seismometer serial number (**4864**). 46 - 47 47 (% class="box warningmessage" %) 48 48 ((( 49 49 NOTE: the 2 at the very end is for "RECORD ON RESTART". The record on restart option ensures that if the logger dies and is powered back up whilst in the field (due to battery charging cycles or other causes) that the recording will resume. (# of blank spaces before this doesn't matter) 50 50 ))) 51 51 52 -== The format for TSAWR loggers is shorter: == 37 +=== The format for TSAWR loggers is shorter: === 53 53 54 54 (% class="box errormessage" %) 55 55 ((( ... ... @@ -68,7 +68,7 @@ 68 68 and seismometer serial number (9999). 69 69 70 70 71 -== The formatting process using the logger: == 56 +=== The formatting process using the logger: === 72 72 73 73 The process for formatting an SD card within the logger is straightforward. Navigate to the "SD INFORMATION" screen and press ERASE SD CARD. This process may take up to a minute. This will result in erasing all files from the card. Upon starting recording, a new 'seed' will be written containing all the information that the logger has been set with FINISH THIS SECTION 74 74 ... ... @@ -80,17 +80,7 @@ 80 80 32Gb card: 122 days @ 250hz or 305 days @ 100hz 81 81 }}} 82 82 83 -== Default Settings == 84 84 85 -As of 2025, the default settings for both LPR (v. 2.7) and TSWAR (v 3.6a) loggers are below. If you're using a broadband instrument, you are essentially good to go without having to program the cards. 86 - 87 -* XX.ANUSR network and station name 88 -* 100 Hz Sample Rate 89 -* 40V pp (or +/- 20 V) gain / Trillium Compact seismometer version 90 -* Record on Restart enabled 91 - 92 -Note that if a user sets the gain incorrectly, this can be fixed later (assuming nothing clipped) by multiplying or dividing by factors of 2. The gain setting can be looked up from the logfile, else you may have to guess from a PSD or other method. 93 - 94 94 = Logger Menus Overview (and setup) = 95 95 96 96 The same menus are used in both the TSAWR and LPR-200 loggers. ... ... @@ -165,20 +165,18 @@ 165 165 166 166 = Instrument Response = 167 167 168 -Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. The ADC (analog todigital)chip inbothloggersoriginallysamplesat 1024000 Hzanddownsamplestowards the outputdata ratevia variousstages.Firstvia a 5thorder SINC filter, thenanother32x via 3-4 2x or 4x FIRfilters.If the outputis below250 Hz,afinal"pure" /5 decimationisdonewithoutanysortofFIRfilter.143 +Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. Depending on the output sample rate (e.g. 100 Hz, 250 Hz, 500 Hz, 1000 Hz) amplitude response is consistently flat up to ~~100 Hz but phase response can vary above 1 Hz at 100 Hz (or 10 Hz at 250 Hz). 169 169 170 -{{info}} 171 -All SINC and FIR filters are performed internally within the logger and all phase delays are accounted for. Thus, the FIR coefficients and delays are not needed/given in the response information. 172 -{{/info}} 145 +The user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. 173 173 174 - Theusercanchoosetoapply a 2ndstage"sensorgain"by selectinganinstrument typeintheetupmenu. Thiseffectivelyselectsa10 Vpp(e.g.shortperiodsensors),20 Vpp, 40 Vpp (mostbroadbandsensors)regime tomatch thesensor's sensitivity. Thishas theeffectof doubling amplitudefrom 10vto20v,or quadruplingfrom 10vto40v.If you haveset your sensorcorrectly(and thesignal isn'tclipped!) youcan "correct"thisbysimply multiplyingyourdata by 0.5etc. Thisgain manifests itself in stage2in the responseinformation.147 +Another important thing to note is that the group delay associated with late stage FIR filters is **automatically applied in the logger**, hence there is no need to apply this in the response. These tend to max out at 0.124 seconds for most output sampling rates (0.062 s for 100 Hz). 175 175 176 -Instrument response can be downloaded from IRIS [[NominalResponseLibrary>>https://ds.iris.edu/ds/nrl/]]if need be, or[[directlyfrom us>>http://auspass.edu.au/data/logger_response]] , orby downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ).149 +Instrument response can be downloaded from IRIS-NRL (v2) if need be, or by downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ) 177 177 178 178 179 -= ANU TerraSAWR (Gen 3, FW 3.5a, 2017- current) = 152 += ANU TerraSAWR (Gen 3, FW 3.5a, 2017?- current) = 180 180 181 - Not sure there'smuchlefttosay154 +Words to describe the TSAWR would go here, if needed 182 182 183 183 184 184 ... ... @@ -187,9 +187,9 @@ 187 187 Ditto the mighty LPR! 188 188 189 189 190 -= ANU "ANUSR" (Gen 1, 2003? - 201 2) =163 += ANU "ANUSR" (Gen 1, 2003? - 2013?) = 191 191 192 -This logger has been retired for a long time and has a different instrument response. It used modular component boards and was powered via an acrylic case of 6 x 6V lantern batteries. There is a somewhat complete one above the CAT lab door if anyone is so inclined to have a look.165 +This logger has been retired for a long time and has a different instrument response. 193 193 194 194 195 195 = References = ... ... @@ -207,11 +207,6 @@ 207 207 ))) 208 208 209 209 210 - 211 - 212 - 213 - 214 - 215 215 (% class="box" %) 216 216 ((( 217 217 = TerraSAWR Specs = ... ... @@ -224,13 +224,12 @@ 224 224 [[image:1704864886951-793.jpg]] 225 225 226 226 |=Size (L x W x H)|30 x 25 x12cm 227 -|=Weight (with battery)| 1.9kg (2.5kg) 195 +|=Weight (with battery)| ~*~*1.9kg (2.5kg) 228 228 |=Battery|((( 229 -Lead-acid 12v, ~~7 -9Ah197 +Lead-acid 12v, ~~7Ah 230 230 231 231 Rechargeable 232 232 ))) 233 -|=Current Firmware|3.5a (Jan 2025) 234 234 235 235 [[image:terrasawr battery.jpg]] 236 236 ))) ... ... @@ -247,18 +247,13 @@ 247 247 [[image:LPR 3.jpg]] 248 248 249 249 |=Size (L x W x H)|42 x 34 x17 cm 250 -|=Weight ( nobattery)|5.5kg217 +|=Weight (with battery)|4.9 kg (7.3 kg) 251 251 |=Battery|((( 252 - NOW: Any 12v battery with tab connectionsthat will fit (ex. the same TSAWR battery)219 +LiFePo4 140Ah 253 253 254 - DISCONTINUED: LiFePo4 140AhRechargeable(shown below).221 +Rechargeable 255 255 ))) 256 -|=Current Firmware|((( 257 -2.6a (old GPS modules) / 2.7a 258 258 259 -Jan 2025 260 -))) 261 - 262 262 [[image:LPR battery.jpg]] 263 263 ))) 264 264 )))
- full_vs_fast.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.robert - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.6 KB - Content