Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/06/27 16:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,19 +10,6 @@ 10 10 ))) 11 11 ))) 12 12 13 -= Power Considerations = 14 - 15 -Both the LPR-200 (or "Low Power Recorder" 200) and TerraSAWR are designed to use as little power as possible, and more or less use the same amount of power. 16 - 17 -At 100 Hz and with a GPS cable connected these loggers draw about 220 mW of power once the screen is off. Adding a sensor (e.g. a Trillium Compact 120) increases this to approximately 400 mW, or 0.4 volt-amps. So, in theory 7 Ah battery should last about 10 days without a solar panel, but in practice it seems to be a bit closer to 8 which may be due to variability in power drain while in getting GPS locks. 18 - 19 -For very sunny environments (latitudes < 30) a 20V 10 Watt solar panel should have no issue keeping these loggers alive over the summer months, and assuming unobstructed skies should also be fine over winter. However there is no harm in using 20 or even a 40 Watt panel, especially for high latitudes, coastal regions, or areas without a full sky view. In theory up to a 60 Watt solar panel is fine, but we don't recommend anything over 40 Watts and that amount of power is already overkill. 20 - 21 -(% class="box infomessage" %) 22 -((( 23 -Power issues are easy and cheap to solve relative to the cost of your experiment, don't skimp! 24 -))) 25 - 26 26 = Data Card Formatting and Information = 27 27 28 28 Both the TerraSAWR and LPR-200 require SD Cards to be formatted in FAT32 filesystem. For 64Gb cards it can be difficult to format in FAT32, but [[software >>http://auspass.edu.au/field/fat32cardformatter.exe]]is available. ANU recommend SanDisk Extreme 150 mb/s cards in either 32 or 64Gb size. We strongly discourage using cards larger than 64Gb, and in general smaller cards are less likely to fail. We have also found that "adapter" cards (e.g. SD to microSD) are prone to having write issues and **strongly** advise against them. ... ... @@ -29,27 +29,25 @@ 29 29 30 30 The loggers can be "pre-programmed" with information (e.g. site name, sampling rate, etc) or they can be programmed in the field using the buttons on the logger. To pre-program the cards you simply edit a text file (named "[[ANUSRSetup.txt>>http://auspass.edu.au/field/ANUSRSetup.txt]]" for the LPRs, or "[[tSAWRSetup.txt>>http://auspass.edu.au/field/tSAWRSetup.txt]]" for the TerraSAWRs) and place it in the root directory on the SDCard. When the logger boots up, it will parse and load this information. 31 31 32 -== The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this: == 19 +=== The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this: === 33 33 34 34 {{{XXX195G0100010034864 2 }}} 35 35 36 -//corresponding to// 23 +corresponding to site XXX19, 24 + network 5G, 25 + sample rate 0100, (i.e. 100 Hz) 26 + "gps interval" 01 (once per hour~-~- don't change), 27 + start mode (always 0), 28 + stop mode (always 0), 29 + seismometer type (3 = broadband (+/- 20V), 2 = Guralp (+/- 10V), 1 = shortperiod (+/- 5V), 30 + and seismometer serial number (4864). 37 37 38 - site **XXX19**, 39 - network **5G**, 40 - sample rate **0100**, (i.e. 100 Hz) 41 - "gps interval" **01** (once per hour~-~- don't change), 42 - start mode (always **0**), 43 - stop mode (always **0**), 44 - seismometer type (**3** = broadband (+/- 20V), 2 = Guralp (+/- 10V), 1 = shortperiod (+/- 5V), 45 - and seismometer serial number (**4864**). 46 - 47 47 (% class="box warningmessage" %) 48 48 ((( 49 49 NOTE: the 2 at the very end is for "RECORD ON RESTART". The record on restart option ensures that if the logger dies and is powered back up whilst in the field (due to battery charging cycles or other causes) that the recording will resume. (# of blank spaces before this doesn't matter) 50 50 ))) 51 51 52 -== The format for TSAWR loggers is shorter: == 37 +=== The format for TSAWR loggers is shorter: === 53 53 54 54 (% class="box errormessage" %) 55 55 ((( ... ... @@ -68,7 +68,7 @@ 68 68 and seismometer serial number (9999). 69 69 70 70 71 -== The formatting process using the logger: == 56 +=== The formatting process using the logger: === 72 72 73 73 The process for formatting an SD card within the logger is straightforward. Navigate to the "SD INFORMATION" screen and press ERASE SD CARD. This process may take up to a minute. This will result in erasing all files from the card. Upon starting recording, a new 'seed' will be written containing all the information that the logger has been set with FINISH THIS SECTION 74 74 ... ... @@ -80,17 +80,7 @@ 80 80 32Gb card: 122 days @ 250hz or 305 days @ 100hz 81 81 }}} 82 82 83 -== Default Settings == 84 84 85 -As of 2025, the default settings for both LPR (v. 2.7) and TSWAR (v 3.6a) loggers are below. If you're using a broadband instrument, you are essentially good to go without having to program the cards. 86 - 87 -* XX.ANUSR network and station name 88 -* 100 Hz Sample Rate 89 -* 40V pp (or +/- 20 V) gain / Trillium Compact seismometer version 90 -* Record on Restart enabled 91 - 92 -Note that if a user sets the gain incorrectly, this can be fixed later (assuming nothing clipped) by multiplying or dividing by factors of 2. The gain setting can be looked up from the logfile, else you may have to guess from a PSD or other method. 93 - 94 94 = Logger Menus Overview (and setup) = 95 95 96 96 The same menus are used in both the TSAWR and LPR-200 loggers. ... ... @@ -101,17 +101,26 @@ 101 101 102 102 This menu also displays the firmware version, battery, external, and solar voltages, and the temperature of the system. 103 103 104 -* Check all Initialisation Parameters are marked as successful. 105 -* Check that solar voltage is above 10 V, otherwise the station will not last long. 79 +==== Upon setup ==== 106 106 81 +- Check all Initialisation Parameters are marked as successful. 82 + 83 +- Check that solar voltage is above 10 V, otherwise the station will not last long. 84 + 85 + 107 107 == Live Seismometer Data == 108 108 109 109 This screen displays real time seismometer data for all 3 axes of the seismometer. Initially, a plot of raw data from all 3 channels is shown. By pressing enter, a high pass filter can be applied showing a more useful plot of all channels. The up and down arrows can be used to change between a view of all channels, individual channels, and all channels on different X axes. 110 110 111 -* Check that all 3 channels are present and are producing a signal. 112 -* Stomp on the ground near where the sensor is installed to check that a signal is being picked up by all 3 channels. 113 -* Common representations of poor signals include channels sloping smoothly from high values to zero, or sharp corners in the plots. 90 +==== Upon setup ==== 114 114 92 +- Check that all 3 channels are present and are producing a signal. 93 + 94 +- Stomp on the ground near where the sensor is installed to check that a signal is being picked up by all 3 channels. 95 + 96 +- Common representations of poor signals include channels sloping smoothly from high values to zero, or sharp corners in the plots. 97 + 98 + 115 115 == GPS Data == 116 116 117 117 This menu displays the status of the stations' GPS connection. The screen lists; UTC time, UTC date, latitude, longitude, altitude, number of satellite connections, and SNR. ... ... @@ -118,10 +118,12 @@ 118 118 119 119 * Check that the station is connected to satellites 120 120 105 + 121 121 == SD Information == 122 122 123 123 The menu lists if the SD card has been initialised, as well as the capacity and space free on the memory card. See "Data card formatting" (above) to see how to format and initialise the inserted SD card. 124 124 110 + 125 125 == System Configuration == 126 126 127 127 This menu is used to set the stations identifiers and parameters. ... ... @@ -165,35 +165,30 @@ 165 165 166 166 = Instrument Response = 167 167 168 -Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. Depending on the output sample rate (e.g. 100 Hz, 250 Hz, 1000 Hz) amplitude response is consistently flat up to ~~100 Hz but phase response can vary above 1 Hz at 100 Hz (or 10 Hz at 250 Hz). 154 +Both the TerraSAWR and LPR-200 use the same ADS1281 analog-to-digital converter chip and are designed to have identical instrument response. Depending on the output sample rate (e.g. 100 Hz, 250 Hz, 500 Hz, 1000 Hz) amplitude response is consistently flat up to ~~100 Hz but phase response can vary above 1 Hz at 100 Hz (or 10 Hz at 250 Hz). 169 169 170 170 The user can choose to apply a 2nd stage "sensor gain" by selecting an instrument type in the setup menu. This effectively selects a 10 Vpp (e.g. short period sensors), 20 Vpp, 40 Vpp (most broadband sensors) regime to match the sensor's sensitivity. This has the effect of doubling amplitude from 10v to 20v, or quadrupling from 10v to 40v. If you have set your sensor correctly (and the signal isn't clipped!) you can "correct" this by simply multiplying your data by 0.5 etc. 171 171 172 172 Another important thing to note is that the group delay associated with late stage FIR filters is **automatically applied in the logger**, hence there is no need to apply this in the response. These tend to max out at 0.124 seconds for most output sampling rates (0.062 s for 100 Hz). 173 173 174 -Instrument response can be downloaded from IRIS [[NominalResponseLibrary>>https://ds.iris.edu/ds/nrl/]]if need be, or[[directlyfrom us>>http://auspass.edu.au/data/logger_response]] , orby downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ).160 +Instrument response can be downloaded from IRIS-NRL (v2) if need be, or by downloading the response of an equivalent sensor at AusPass (e.g. get_stations(level='response') ) 175 175 176 -The response info from IRIS-NRL is the "full" version which (in theory!) perfectly describes the data logger's bias on the data. However this is in many way overkill and at the cost of 1) increased metadata size and, more importantly, 2) increased CPU demand in the response removal process. Testing has shown that for signals below 100 Hz, the "full" response offers little to no benefit and can increase the time it takes to remove the response for a 1 hour window of 100Hz data by a factor of x20 or more. For earthquake arrival data this is often negligible, but for data intensive tasks like ambient noise cross-correlations this can be a severe hindrance. Thus we have created a parallel version of this response which removes the SINC and FIR filters completely. These are labelled "fast" in our [[local response archive>>http://auspass.edu.au/data/logger_response]] and essentially truncate response stages 3 onwards into a "fake" decimation step from 1024000 Hz to the desired output samplerate with no filtering whatsoever. 177 177 178 - Inthebelow we show bothresponses applied to a test signal with a frequency rangeof 1000 seconds to 100 Hz. The maximum discrepancy in signal is less than 0.01%(1.0001) which is far below what you should expect from the mechanicalinconsistencies intrinsic to the sensor itself. Thus,westrongly advise users employ the "fast" version of this response information and it is what we use for our networks by default.If youare recording at 1000 Hz,or care deeply about signals above 100 Hz (so recorded at250or1000Hz), pleaseuse the fullresponse. Any questions,please ask!163 += ANU TerraSAWR (Gen 3, FW 3.5a, 2017?- current) = 179 179 180 - [[Testing the "full" and"fast"versionsof the ANUdata logger response on synthetic250 Hz data from 1000 secondsto 100hertz.Forall intents andpurposes,they are identical.>>image:full_vs_fast.png||data-xwiki-image-style-alignment="center"]]165 +Words to describe the TSAWR would go here, if needed 181 181 167 + 182 182 183 -= ANU TerraSAWR (Gen 3, FW 3.5a, 2017- current) = 184 184 185 -Not sure there's much left to say 186 - 187 - 188 - 189 189 = ANU LPR-200 (Gen 2, FW 2.6a/2.7a, 2013 - current) = 190 190 191 191 Ditto the mighty LPR! 192 192 193 193 194 -= ANU "ANUSR" (Gen 1, 2003? - 201 2) =175 += ANU "ANUSR" (Gen 1, 2003? - 2013?) = 195 195 196 -This logger has been retired for a long time and has a different instrument response. It used modular component boards and was powered via an acrylic case of 6 x 6V lantern batteries. There is a somewhat complete one above the CAT lab door if anyone is so inclined to have a look.177 +This logger has been retired for a long time and has a different instrument response. 197 197 198 198 199 199 = References = ... ... @@ -211,10 +211,6 @@ 211 211 ))) 212 212 213 213 214 - 215 - 216 - 217 - 218 218 (% class="box" %) 219 219 ((( 220 220 = TerraSAWR Specs = ... ... @@ -227,13 +227,12 @@ 227 227 [[image:1704864886951-793.jpg]] 228 228 229 229 |=Size (L x W x H)|30 x 25 x12cm 230 -|=Weight (with battery)| 1.9kg (2.5kg) 207 +|=Weight (with battery)| ~*~*1.9kg (2.5kg) 231 231 |=Battery|((( 232 -Lead-acid 12v, ~~7 -9Ah209 +Lead-acid 12v, ~~7Ah 233 233 234 234 Rechargeable 235 235 ))) 236 -|=Current Firmware|3.5a (Jan 2025) 237 237 238 238 [[image:terrasawr battery.jpg]] 239 239 ))) ... ... @@ -250,18 +250,13 @@ 250 250 [[image:LPR 3.jpg]] 251 251 252 252 |=Size (L x W x H)|42 x 34 x17 cm 253 -|=Weight ( nobattery)|5.5kg229 +|=Weight (with battery)|4.9 kg (7.3 kg) 254 254 |=Battery|((( 255 - NOW: Any 12v battery with tab connectionsthat will fit (ex. the same TSAWR battery)231 +LiFePo4 140Ah 256 256 257 - DISCONTINUED: LiFePo4 140AhRechargeable(shown below).233 +Rechargeable 258 258 ))) 259 -|=Current Firmware|((( 260 -2.6a (old GPS modules) / 2.7a 261 261 262 -Jan 2025 263 -))) 264 - 265 265 [[image:LPR battery.jpg]] 266 266 ))) 267 267 )))
- full_vs_fast.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.robert - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.6 KB - Content