Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/06/27 16:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. JackD1 +XWiki.robert - Content
-
... ... @@ -1,15 +1,7 @@ 1 -(% class="row" %) 2 -((( 3 -(% class="col-xs-12 col-sm-8" %) 4 -((( 5 -(% class="jumbotron" %) 6 -((( 7 -(% class="container" %) 8 -((( 1 + 9 9 ANU has designed and built three generations of seismic data recorders, two of which (the small yellow TerraSAWR and the larger beige LPR-200) are still in use today. Despite their contrasting appearance, they both use the same software, data cards, and have the same instrument response. 10 -))) 11 -))) 12 12 4 + 13 13 = Data Card Formatting and Information = 14 14 15 15 Both the TerraSAWR and LPR-200 require SD Cards to be formatted in FAT32 filesystem. For 64Gb cards it can be difficult to format in FAT32, but [[software >>http://auspass.edu.au/field/fat32cardformatter.exe]]is available. ANU recommend SanDisk Extreme 150 mb/s cards in either 32 or 64Gb size. We strongly discourage using cards larger than 64Gb, and in general smaller cards are less likely to fail. We have also found that "adapter" cards (e.g. SD to microSD) are prone to having write issues and **strongly** advise against them. ... ... @@ -57,6 +57,7 @@ 57 57 58 58 The process for formatting an SD card within the logger is straightforward. Navigate to the "SD INFORMATION" screen and press ERASE SD CARD. This process may take up to a minute. This will result in erasing all files from the card. Upon starting recording, a new 'seed' will be written containing all the information that the logger has been set with FINISH THIS SECTION 59 59 52 +[[image:original_0747763c-e3dd-4667-b897-833f12c8e0b8_20241219_130604.jpg||height="240" width="298"]] 60 60 61 61 Here is a general guideline for how much data you can expect to fit on a card: 62 62 ... ... @@ -67,7 +67,7 @@ 67 67 68 68 = Logger Menus Overview (and setup) = 69 69 70 -The same menus are used in both t ypesofloggers.63 +The same menus are used in both the TSAWR and LPR-200 loggers. 71 71 72 72 == System Information == 73 73 ... ... @@ -146,17 +146,18 @@ 146 146 NOTE: Ensure the 'RECORD ON RESTART' option is marked with a cross. 147 147 ))) 148 148 142 +(% class="wikigeneratedid" %) 143 +[[image:original_2b83fcf5-ee5a-4375-bab1-2d738e4ffe8c_20241219_130646.jpg||height="234" width="289"]] 144 + 149 149 == STA/LTA Configuration == 150 150 151 - -147 +The Short Term Average and Long Term Average Configuration screen is no longer used. 152 152 153 -= = 154 154 155 155 = LogFile Conversion Script = 156 156 157 157 Both the TSAWR and LPR-200 write logging information as a binary "dat" file which includes GPS time syncs, temperatures, battery power, and position. To convert them into ASCII you can read, use [[THIS PYTHON SCRIPT>>http://auspass.edu.au/field/anusr_log.py]]. 158 158 159 -= = 160 160 161 161 = Instrument Response = 162 162 ... ... @@ -206,7 +206,7 @@ 206 206 = References = 207 207 208 208 * [[PDF Manual>>http://auspass.edu.au/field/LPR-200_Instruction_Manual.pdf]] 209 -))) 203 +~)~)~) 210 210 211 211 (% class="col-xs-12 col-sm-4" %) 212 212 ((( ... ... @@ -262,4 +262,5 @@ 262 262 [[image:LPR battery.jpg]] 263 263 ))) 264 264 ))) 265 -))) 259 + 260 +~)~)~)
- original_0747763c-e3dd-4667-b897-833f12c8e0b8_20241219_130604.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +858.4 KB - Content
- original_2b83fcf5-ee5a-4375-bab1-2d738e4ffe8c_20241219_130646.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +890.3 KB - Content