Changes for page ANU Seismic Data Loggers
Last modified by robert on 2025/06/20 12:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -54,10 +54,32 @@ 54 54 Here is a general guideline for how much data you can expect to fit on a card: 55 55 56 56 {{{ 64Gb card: 245 days @ 250hz or 610 days @ 100hz 57 - 32Gb card: 122 days @ 250hz or 305 days @ 100hz}}} 57 + 32Gb card: 122 days @ 250hz or 305 days @ 100hz 58 +}}} 58 58 59 59 61 += Logger Menus Overview (and setup) = 60 60 63 +== System Information == 64 + 65 +This menu provides an overview of the status of the station. Under 'Initialisation Parameters', the status of systems that are initialised upon powering on the logger can be checked. 66 + 67 +This menu also displays the firmware version, battery, external, and solar voltages, and the temperature of the system. 68 + 69 +==== Upon setup ==== 70 + 71 +- Check all Initialisation Parameters are marked as successful 72 + 73 +{{info}} 74 + 75 +{{/info}} 76 + 77 +== Live Seismometer Data == 78 + 79 +This screen displays real time seismometer data for all 3 axes of the seismometer. Initially, a plot of raw data from all 3 channels is shown. By pressing enter, a high pass filter can be applied showing a more useful plot of all channels. The up and down arrows can be used to change between a view of all channels, individual channels, and all channels on different X axes. 80 + 81 + 82 + 61 61 = LogFile Conversion Script = 62 62 63 63 Both the TSAWR and LPR-200 write logging information as a binary "dat" file which includes GPS time syncs, temperatures, battery power, and position. To convert them into ASCII you can read, use [[THIS PYTHON SCRIPT>>http://auspass.edu.au/field/anusr_log.py]].