Changes for page ANU Seismic Data Loggers

Last modified by robert on 2025/06/15 14:13

From version 30.1
edited by Jack Dent
on 2024/12/19 10:42
Change comment: There is no comment for this version
To version 28.1
edited by robert
on 2024/11/11 20:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.JackD
1 +XWiki.robert
Content
... ... @@ -16,41 +16,28 @@
16 16  
17 17  The loggers can be "pre-programmed" with information (e.g. site name, sampling rate, etc) or they can be programmed in the field using the buttons on the logger. To pre-program the cards you simply edit a text file (named "[[ANUSRSetup.txt>>http://auspass.edu.au/field/ANUSRSetup.txt]]" for the LPRs, or "[[tSAWRSetup.txt>>http://auspass.edu.au/field/tSAWRSetup.txt]]" for the TerraSAWRs) and place it in the root directory on the SDCard. When the logger boots up, it will parse and load this information.
18 18  
19 -=== The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this: ===
19 +The format for ANUSRSetup.txt / LPR200s will be a single line of text that looks like this:
20 20  
21 21  {{{XXX195G0100010034864 2 }}}
22 22  
23 23  corresponding to site XXX19,
24 24   network 5G,
25 - sample rate 0100, (i.e. 100 Hz)
25 + sample rate 0100, (e.g. 100 hz)
26 26   "gps interval" 01 (once per hour~-~- don't change),
27 27   start mode (always 0),
28 28   stop mode (always 0),
29 29   seismometer type (3 = broadband (+/- 20V), 1 = shortperiod (+/- 5V),
30 30   and seismometer serial number (4864).
31 + the 2 at the very end is for "start recording on power"
32 + and is vital to have this set so the logger will resume recording on its own if it experiences a power cycle. (# of blank spaces before this doesn't matter)
31 31  
32 -(% class="box warningmessage" %)
33 -(((
34 -NOTE: the 2 at the very end is for "start recording on power" and is vital to have this set so the logger will resume recording on its own if it experiences a power cycle. (# of blank spaces before this doesn't matter)
35 -)))
34 +the TSAWRs are a bit shorter as they don't have an option to set the "gps sync"
36 36  
37 -=== The format for TSAWR loggers are a bit shorter as they don't have an option to set the "gps sync" ===
36 +{{{SITE1XX02500039999 2}}}
38 38  
39 -SITE1XX02500039999 2
38 +which would set up a Trillium Compact with serial 9999 named XX.SITE1 at 250hz sample rate.
40 40  
41 -corresponding to site XX.SITE1,
42 - sample rate 0250, (i.e. 250 Hz)
43 - start mode (always 0),
44 - stop mode (always 0),
45 - seismometer type (3 = broadband (+/- 20V), 1 = shortperiod (+/- 5V),
46 - and seismometer serial number (9999).
47 47  
48 -
49 -=== The formatting process using the logger: ===
50 -
51 -The process for formatting an SD card within the logger is straightforward. Navigate to the "SD INFORMATION" screen and press ERASE SD CARD. This process may take up to a minute. This will result in erasing all files from the card. Upon starting recording, a new 'seed' will be written containing all the information that the logger has been set with FINISH THIS SECTION
52 -
53 -
54 54  Here is a general guideline for how much data you can expect to fit on a card:
55 55  
56 56  {{{ 64Gb card: 245 days @ 250hz or 610 days @ 100hz